ProZ.com global directory of translation services
 The translation workplace
Ideas
KudoZ home » English to Bulgarian » Electronics / Elect Eng

anti-surge

Bulgarian translation: (за ел. предпазител) със забавено действие; бавнодействащ


Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
English term or phrase:anti-surge
Bulgarian translation:(за ел. предпазител) със забавено действие; бавнодействащ
Entered by: invguy
Options:
- Contribute to this entry
- Include in personal glossary

13:20 Apr 21, 2011
English to Bulgarian translations [PRO]
Tech/Engineering - Electronics / Elect Eng / Control Module
English term or phrase: anti-surge
Здравейте,
Търся помощ за точния превод на израза на български.
Терминът се среща при описание на изходите на модула.
(Recommended Maximum Fuse 15A anti-surge)
Supplies the module (2A anti-surge requirement) and all output relays
Благодаря предварително!
Svetymil
Local time: 19:38
(в случая) със забавено действие; бавнодействащ
Explanation:
Anti-surge protection действително значи защита от пренапрежение. Тук обаче (и в двата случая) става дума за предпазители, т.е. за максималнотокова защита. При предпазителите anti-surge = slow-blow = time delay (fuse).

The time delay fuse (also known as anti-surge, or slow-blow) are designed to allow a current which is above the rated value of the fuse to flow for a short period of time without the fuse blowing.
http://en.wikipedia.org/wiki/Fuse_(electrical)

Fuse Type
There are three basic types of fuses:
(1) Slow Blow/Time Lag/ Time Delay fuses
(2) Fast acting fuses
(3) Very fast acting fuses
. . . . .
Slow-blow fuse allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short circuits. Slow-blow fuses are ideal for circuits with a transient surge or power-on inrush. These circuits include: motors, transformers, incandescent lamps and capacitate loads. This inrush may be many times the circuit's full load amperes. Slow-blow fuses allow close rating of the fuse without nuisance opening. Typically, Slow Blow fuses are rated between 125% to 150% of the circuit's full load amperes.
http://www.circuitprotection.ca/fuseology.html

Slow Blow Fuses help provide overcurrent protection on systems
that experience large and frequent current surges as part of their
normal operation, and feature clear time characteristics of:
• 4 hours minimum at 100% of rated current;
• 120 seconds maximum and 1 second minimum at 200% of
rated current;
• 3 seconds maximum and 0.1 second minimum at 300% rated
current; and
• ranges from 0.0005 seconds minimum to 0.05 second
maximum at 800% of rated current.
http://docs.google.com/viewer?a=v&q=cache:f-KL88RmfwIJ:www.c...

На български се използва и "бавностопяем" (НЕ "бавнотопим"!), но то е по-разговорно.
Selected response from:

invguy
Bulgaria
Local time: 19:38
Grading comment
Благодаря!
4 KudoZ points were awarded for this answer



Summary of answers provided
4(в случая) със забавено действие; бавнодействащ
invguy
4устойчивост на пренапрежение
Yavor Popov
4антипомпаженIrolinda
3Защита от пренапрежение
Denis Shepelev


  

Answers


13 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
антипомпажен


Explanation:
Термина се среща в съчетания като антипомпажен кран, антипомпажна система за регулиране на компресора, антипомпажен клапан, т.н.

Example sentence(s):
  • "Настройка на 2 (два) броя антипомпажни регулатори, от които 1 бр. на КС „Кардам-2” и 1 бр. на КС „Лозенец”
Irolinda
Local time: 19:38
Native speaker of: Native in BulgarianBulgarian, Native in RussianRussian

Peer comments on this answer (and responses from the answerer)
neutral  klyunchev: Това не е ли за газопреносни инсталации? Имал съм го в такъв контекст. Тук е ел./елн.
9 hrs
Login to enter a peer comment (or grade)

25 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
устойчивост на пренапрежение


Explanation:
http://www.multitran.ru/c/m.exe?l1=1&l2=2&s=antisurge

Yavor Popov
Bulgaria
Local time: 19:38
Native speaker of: Native in BulgarianBulgarian
PRO pts in category: 12

Peer comments on this answer (and responses from the answerer)
neutral  klyunchev: Според мен тук anti-surge е прилагателно. Ми да, в линка е устойчив на пренапрежения.
9 hrs
Login to enter a peer comment (or grade)

27 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5
Защита от пренапрежение


Explanation:
Предпазител 15А със защита от пренапрежение.

Нещо такова.

Example sentence(s):
  • ПРЕДПАЗИТЕЛ ОТ ПРЕНАПРЕЖЕНИЕ 110V-240V 16A SURGE PROTECTOR EL-SPP01
Denis Shepelev
Local time: 19:38
Works in field
Native speaker of: Native in BulgarianBulgarian, Native in RussianRussian
PRO pts in category: 20

Peer comments on this answer (and responses from the answerer)
neutral  klyunchev: Според мен тук anti-surge е прилагателно.
9 hrs
  -> Естествено, че е прилагателно.
Login to enter a peer comment (or grade)

20 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
(в случая) със забавено действие; бавнодействащ


Explanation:
Anti-surge protection действително значи защита от пренапрежение. Тук обаче (и в двата случая) става дума за предпазители, т.е. за максималнотокова защита. При предпазителите anti-surge = slow-blow = time delay (fuse).

The time delay fuse (also known as anti-surge, or slow-blow) are designed to allow a current which is above the rated value of the fuse to flow for a short period of time without the fuse blowing.
http://en.wikipedia.org/wiki/Fuse_(electrical)

Fuse Type
There are three basic types of fuses:
(1) Slow Blow/Time Lag/ Time Delay fuses
(2) Fast acting fuses
(3) Very fast acting fuses
. . . . .
Slow-blow fuse allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short circuits. Slow-blow fuses are ideal for circuits with a transient surge or power-on inrush. These circuits include: motors, transformers, incandescent lamps and capacitate loads. This inrush may be many times the circuit's full load amperes. Slow-blow fuses allow close rating of the fuse without nuisance opening. Typically, Slow Blow fuses are rated between 125% to 150% of the circuit's full load amperes.
http://www.circuitprotection.ca/fuseology.html

Slow Blow Fuses help provide overcurrent protection on systems
that experience large and frequent current surges as part of their
normal operation, and feature clear time characteristics of:
• 4 hours minimum at 100% of rated current;
• 120 seconds maximum and 1 second minimum at 200% of
rated current;
• 3 seconds maximum and 0.1 second minimum at 300% rated
current; and
• ranges from 0.0005 seconds minimum to 0.05 second
maximum at 800% of rated current.
http://docs.google.com/viewer?a=v&q=cache:f-KL88RmfwIJ:www.c...

На български се използва и "бавностопяем" (НЕ "бавнотопим"!), но то е по-разговорно.

invguy
Bulgaria
Local time: 19:38
Specializes in field
Native speaker of: Native in BulgarianBulgarian
PRO pts in category: 77
Grading comment
Благодаря!
Login to enter a peer comment (or grade)




Return to KudoZ list


Changes made by editors
Apr 24, 2011 - Changes made by invguy:
Created KOG entryKudoZ term => KOG term


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also: