ProZ.com global directory of translation services
 The translation workplace
Ideas
KudoZ home » English to French » Medical: Cardiology

yields radial strength

French translation: perd graduellement sa force (rigidité) radiale


Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
14:02 Jan 15, 2011
English to French translations [PRO]
Medical - Medical: Cardiology
English term or phrase: yields radial strength
3 Phases of XX

Revascularization
XXX offers revascularization performance consistent with best-in-class PCIs
Restoration 
XXX gradually yields radial strength and loss of the vascular scaffold mass, which allows for the return of natural vasomotion, restoring natural function
Resorption
XXX slowly begins to dissolve, acting as an inert implant that is resorbed by the body, allowing for an increase in lumen size as a result of a decrease in plaque
Krystrad
Local time: 12:03
French translation:perd graduellement sa force (rigidité) radiale
Explanation:
--

--------------------------------------------------
Note added at 4 hrs (2011-01-15 18:36:57 GMT)
--------------------------------------------------

ou 'résistance radiale à la compression'

http://www.biomeca.org/Fr/Recherche/vasculaire8.html
Selected response from:

Guillaume St-G
Canada
Local time: 06:03
Grading comment
merci
4 KudoZ points were awarded for this answer



Summary of answers provided
5 +2perd graduellement sa force (rigidité) radiale
Guillaume St-G
4exerce une force radialexxxLionel_M
3 -1perd peu à peu de sa force centrifugeImanol


Discussion entries: 14





  

Answers


30 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): -1
perd peu à peu de sa force centrifuge


Explanation:
"Une endoprothèse est un cylindre de matériel grillagé expansible déployé à demeure dans une artère. Il exerce une force centrifuge sur la paroi artérielle, avec conservation d'une bonne ouverture de la lumière, et la restauration d'un paroi artérielle plus lisse"
http://books.google.fr/books?id=NQFms0Cu1Y0C&pg=PT38&lpg=PT3...


--------------------------------------------------
Note added at 30 mins (2011-01-15 14:33:55 GMT)
--------------------------------------------------

Pardon : d'unE paroi artérielle plus lisse

Imanol
Local time: 12:03
Works in field
Native speaker of: Native in FrenchFrench

Peer comments on this answer (and responses from the answerer)
disagree  Germaine: on comprend ce que les auteurs veulent dire, mais à mon humble avis, ce n'est pas (par définition) le mot pour le dire!
6 hrs
  -> La force radiale, en français, peut être centripète, alors que là il s'agit clairement, à ce qu'il me semble, d'une force centrifuge (de l'intérieur vers l'extérieur), qui va diminuant

disagree  Mohamed Mehenoun: Je ne lis pas le même contexte, votre référence parle d'endoprothèse...Les auteurs ne se trompent pas, c'est juste vous qui avez utilisé la référence dans un contexte qui n'est pas le sien !
6 hrs
  -> Donc les auteurs du livre cité en référence se trompent. C'est possible.

agree  SJLD: ne mérite pas des disagrees - il s'agit bien d'une endoprothèse artérielle - et cette proposition est correcte sur le plan "physique"
19 hrs
  -> Merci beaucoup - je pense que les deux solutions (radial et centrifuge) sont acceptables, avec du pour et du contre pour l'une comme pour l'autre.
Login to enter a peer comment (or grade)

53 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
exerce une force radiale


Explanation:
Endoprothèse oesophagienne - Micro-tech|Disposable Biopsy Forceps ...
Puis, l'endoprothèse exerce une légère force radiale et agit sur la paroi interne de l'oesophage afin de dilater progressivement la sténose et de ...
www.micro-tech.com.cn/dyz/fr/Stent.asp - En cache
Endoprothèse trachéale - Micro-tech|Disposable Biopsy Forceps ...
Puis, l'endoprothèse exerce une légère force radiale et agit sur la paroi ...
www.micro-tech.com.cn/dyz/fr/Stent_2.asp - En cache
Plus de résultats de micro-tech.com.cn
Article gratuit - Journal de Pharmacie Clinique
de FB Pribat - Autres articles
En effet, ces endoprothèses, véritables treillis métalliques, exercent une force radiale qui permet de prévenir la constriction adventicielle chronique ...
www.john-libbey-eurotext.fr/fr/revues/.../article.phtml - Pages similaires
[PDF] DIU de Cardiologie Interventionnelle 2° année 2009-2010 ...
Format de fichier: PDF/Adobe Acrobat - Afficher
Objectif : connaître les aspects mécaniques des endoprothèses que l'on utilise ... fondamental en exerçant une force radiale qui permet de déployer le stent de ... qu'exerce l'artère sur le stent (un stent déployé n'exerce pas de force ...
www.sfcardio.fr/groupes/...et...et.../notes_finet.pdf
Angioplastie des membres inférieurs - Encyclopédie médicale - Medix
Elle est bien gérée par la mise en place d'une endoprothèse couverte sur le .... et la force radiale exercée contre celle-ci évite toute migration. ... Elles ont une force radiale importante mais leur longueur est souvent limitée. ...
www.medix.free.fr/rub/angioplastie-membres-inferieurs.php - En cache
Étude RES 1CE | theheart.org en français
20 mai 2009... en place une structure métallique qui exerce une force radiale dans ... Le nouveau stent, dit Nevo (Cordis), est un stent à élution de ...
www.theheart.org/article/972109.do - En cache - Pages similaires

http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6W...


--------------------------------------------------
Note added at 55 min (2011-01-15 14:58:14 GMT)
--------------------------------------------------

The influence of physical stent parameters upon restenosis
Paramètres physiques des stents dans la resténose


Allison C. Morton, David Crossman and Julian Gunn,
Cardiovascular Research Unit, Northern General Hospital, Clinical Sciences Building, University of Sheffield, Herries Road, Sheffield S5 7AU, UK
Received 25 February 2004; accepted 16 March 2004. Available online 9 April 2004.
Abstract
In this paper we examine whether the structure, geometry and dimensions of coronary stents influence the occurrence of restenosis. Whilst many consider these parameters to be less important since the advent of drug-eluting stents, this view reveals a poor appreciation of the technological development of stents over the last 18 years. Early ‘slotted tube’ stents were completely inflexible and posed major problems for delivery; and early ‘coil’ stents had poor radial strength, allowing considerable tissue prolapse. Nowadays, we are used to greatly improved physical stent parameters, which provide better deliverability, visibility, procedural success and scaffolding performance. Many of these physical parameters also impact upon restenosis, even in the current era of drug-eluting stent. In this paper we examine the contribution of mode of expansion (self vs. balloon-expandable), design (coil vs. tube), length and width to restenosis. We also consider the more subtle influence of advanced slotted tube vs. modular design, percent metal coverage, strut thickness, strut shape, surface smoothness and alloy composition.
Résumé
Cet article évalue les éventuelles corrélations entre la structure, la géométrie, les dimensions des stents coronaires et la survenue éventuelle d'une resténose. Bien que ces paramètres semblent moins importants depuis l'arrivée des stents « actifs », cette revue met en évidence les développements technologiques des stents sur les 18 dernières années. Les stents « slotted tubes » étaient totalement inflexibles et posaient des problèmes majeurs pour la mise en place. Les stents « coil » avaient une force radiale insuffisante pouvant entraîner un prolapsus tissulaire. Actuellement, les paramètres physiques des stents permettent un meilleur largage, une meilleure visibilité, un meilleur soutien et un succès procédural plus important. Plusieurs de ces paramètres physiques ont un impact sur la resténose, même dans l'aire des stents actifs. Dans cet article, nous examinons l'importance du mode d'expansion (self vs balloon-expandable), la structure (coil vs tube), la longueur et la largeur des endoprothèses sur la resténose.
Nous évaluons enfin l'influence de la structure modulaire ou tubulaire, du pourcentage de la couverture en métal, de l'épaisseur et de la surface des mailles dans leur relation avec la resténose.
Artery; Stent; Geometry; Design; Restenosis

(see above mentionned link)

xxxLionel_M
Local time: 12:03
Specializes in field
Native speaker of: Native in FrenchFrench
PRO pts in category: 28
Login to enter a peer comment (or grade)

4 hrs   confidence: Answerer confidence 5/5 peer agreement (net): +2
perd graduellement sa force (rigidité) radiale


Explanation:
--

--------------------------------------------------
Note added at 4 hrs (2011-01-15 18:36:57 GMT)
--------------------------------------------------

ou 'résistance radiale à la compression'

http://www.biomeca.org/Fr/Recherche/vasculaire8.html

Guillaume St-G
Canada
Local time: 06:03
Works in field
Native speaker of: Native in FrenchFrench, Native in ThaiThai
PRO pts in category: 4
Grading comment
merci

Peer comments on this answer (and responses from the answerer)
agree  SJLD
14 hrs
  -> merci!

agree  kashew
17 hrs
  -> merci!
Login to enter a peer comment (or grade)




Return to KudoZ list


Changes made by editors
Jan 15, 2011 - Changes made by Stéphanie Soudais:
FieldOther => Medical


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also: