to lock out the wrong disconnect

German translation: den falschen Trennschalter gegen Wiedereinschalten sichern

Advertisement

Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
English term or phrase:to lock out the wrong disconnect
German translation:den falschen Trennschalter gegen Wiedereinschalten sichern
Entered by: BHL
Options:
- Contribute to this entry
- Include in personal glossary

08:48 Apr 10, 2007
English to German translations [PRO]
Tech/Engineering - Engineering (general) / Arbeitssicherheit
English term or phrase: to lock out the wrong disconnect
Aus einem Arbeitsbuch zur Arbeitssicherheit:

Lockout/tagout can sometimes be complicated and require specific training at most work places. If you don't know the exact lockout/tagout procedure for a piece of equipment, you should
□ guess and hope you are right
□ ask someone who knows

Testing the lockout is a good idea because

□ it takes longer and most people are paid by the hour
□ people have made mistakes *by locking out the wrong disconnect*

25. The people who were seriously injured or killed because *the wrong
disconnect was locked out* didn't test it properly.
□ true
□ false

Nochmals danke für Eure Hilfe.
BHL
Local time: 06:16
den falschen Trennschalter gegen Wiedereinschalten sichern
Explanation:
Disconnect ist das Teil, das die Anlage von der Energieversorgung trennt (und zwar im Regelfall, nicht im Notfall - bei einem Not-Aus-Schalter können und dürfen Anlagenteile weiterhin Spannung führen), lockout ist das Sichern gegen Wiedereinschalten (vgl. vorherige Kudoze)
Selected response from:

Klaus Herrmann
Germany
Local time: 06:16
Grading comment
Danke Klaus.
4 KudoZ points were awarded for this answer

Advertisement


Summary of answers provided
4 +4den falschen Trennschalter gegen Wiedereinschalten sichern
Klaus Herrmann
3 -1Betätigung des falschen (Not)-Aus-Schalters
Manuela Junghans


  

Answers


9 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): -1
Betätigung des falschen (Not)-Aus-Schalters


Explanation:
-

Manuela Junghans
United Kingdom
Local time: 05:16
Specializes in field
Native speaker of: Native in GermanGerman
PRO pts in category: 26

Peer comments on this answer (and responses from the answerer)
disagree  Klaus Herrmann: Sorry, aber es ist weder die Betätigung (sondern Sichern gegen Wiedereinschalten) noch ein Notausschalter (sondern ein Trennschalter)
6 mins
Login to enter a peer comment (or grade)

18 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +4
den falschen Trennschalter gegen Wiedereinschalten sichern


Explanation:
Disconnect ist das Teil, das die Anlage von der Energieversorgung trennt (und zwar im Regelfall, nicht im Notfall - bei einem Not-Aus-Schalter können und dürfen Anlagenteile weiterhin Spannung führen), lockout ist das Sichern gegen Wiedereinschalten (vgl. vorherige Kudoze)

Klaus Herrmann
Germany
Local time: 06:16
Works in field
Native speaker of: Native in GermanGerman
PRO pts in category: 266
Grading comment
Danke Klaus.

Peer comments on this answer (and responses from the answerer)
agree  Steffen Walter: Womit wir wieder mal beim Thema wären :-)
5 mins

agree  Capesha
8 mins

agree  Manuela Junghans
13 mins

agree  Lars Helbig
23 mins
Login to enter a peer comment (or grade)




Return to KudoZ list


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also:



Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search