English term or phrase: deadband
Complete listing of all Control setpoint values, Deadbands, Timing Calculated values, Alarm values, etc.

Monitor compressor slide valve position. There shall be an Operator adjustable setpoint and deadband for each compressor for the operation of the side-port solenoid
Laura_
Uruguay
Local time: 19:23
banda muerta
Explanation:
<html> <head> </head><body><pre>Date: Wed, 21 Feb 2001 08:15:53 ...
... Date: Wed, 21 Feb 2001 09:34:01 -0500 From: Dyran <translator@xlation.com>
deadband o dead band = banda muerta; frecuencia de radio que no está en uso ...
www.gsi.dit.upm.es/~gfer/spanglish/deadband - 6k - En caché - Páginas similares

[PDF] 110-1034 Sp.qxd
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La pantalla mostrará: AUTOCHANGE DEADBAND. 6. Oprima el botón o para ajustar la
banda muerta entre 2.0°Fy 8.0°F (1.0°Cy 4.5°C). 7. Espere cinco segundos ...
www.icca.invensys.com/manuals/ robertshaw/110-1034_Sp.pdf - Páginas similares

[PDF] 110-975D Sp.qxd
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La pantalla mostrará: AUTOCHANGE DEADBAND. 7. Oprima el botón o para ajustar la
banda muerta entre 2°Fy 8°F (1.0°Cy 4.5°C). 8. Espere 3 segundos u oprima ...
www.icca.invensys.com/manuals/ robertshaw/110-975D_Sp.pdf - Páginas similares

[PDF] Serie EFP Posicionador Amigable al Ambiente
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... Cuando la señal de entrada es igual a la señal de alimentación con la especifi-
cación "banda-muerta" (deadband), el EFP no moviliza el solenoide. ...
www.bpe950.com/pdf-documents/ sales/sales-sp-0102-efp.pdf - Páginas similares

[PDF] Series VRP-SB-PID Controlador para Gas Natural
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... Adjustment VRP-SB-PID Adjustments Setpoint Adjustment Deadband (Sensitivity) Derivative ... aproximado
25 libras (9.1 kg) Mínimo de Banda-Muerta 0.2% presión de ...
www.bpe950.com/pdf-documents/sales/ sales-sp-0102-vrp-sb-pid.pdf
Selected response from:

Maria Luisa Duarte
Spain
Local time: 00:23
Grading comment
Many thanks!
4 KudoZ points were awarded for this answer

Advertisement


Summary of answers provided
5banda muerta
Maria Luisa Duarte
3banda inactiva
ruth granados


  

Answers


8 mins   confidence: Answerer confidence 5/5
banda muerta


Explanation:
<html> <head> </head><body><pre>Date: Wed, 21 Feb 2001 08:15:53 ...
... Date: Wed, 21 Feb 2001 09:34:01 -0500 From: Dyran <translator@xlation.com>
deadband o dead band = banda muerta; frecuencia de radio que no está en uso ...
www.gsi.dit.upm.es/~gfer/spanglish/deadband - 6k - En caché - Páginas similares

[PDF] 110-1034 Sp.qxd
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La pantalla mostrará: AUTOCHANGE DEADBAND. 6. Oprima el botón o para ajustar la
banda muerta entre 2.0°Fy 8.0°F (1.0°Cy 4.5°C). 7. Espere cinco segundos ...
www.icca.invensys.com/manuals/ robertshaw/110-1034_Sp.pdf - Páginas similares

[PDF] 110-975D Sp.qxd
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La pantalla mostrará: AUTOCHANGE DEADBAND. 7. Oprima el botón o para ajustar la
banda muerta entre 2°Fy 8°F (1.0°Cy 4.5°C). 8. Espere 3 segundos u oprima ...
www.icca.invensys.com/manuals/ robertshaw/110-975D_Sp.pdf - Páginas similares

[PDF] Serie EFP Posicionador Amigable al Ambiente
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... Cuando la señal de entrada es igual a la señal de alimentación con la especifi-
cación "banda-muerta" (deadband), el EFP no moviliza el solenoide. ...
www.bpe950.com/pdf-documents/ sales/sales-sp-0102-efp.pdf - Páginas similares

[PDF] Series VRP-SB-PID Controlador para Gas Natural
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... Adjustment VRP-SB-PID Adjustments Setpoint Adjustment Deadband (Sensitivity) Derivative ... aproximado
25 libras (9.1 kg) Mínimo de Banda-Muerta 0.2% presión de ...
www.bpe950.com/pdf-documents/sales/ sales-sp-0102-vrp-sb-pid.pdf


Maria Luisa Duarte
Spain
Local time: 00:23
Specializes in field
Native speaker of: Native in EnglishEnglish, Native in PortuguesePortuguese
PRO pts in category: 116
Grading comment
Many thanks!
Login to enter a peer comment (or grade)

12 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5
banda inactiva


Explanation:
En el diccionario técnico Routledge pone:

Deadband: ELEC ENG banda inactiva

Espero que te sirva.

Ruth

ruth granados
Local time: 00:23
Native speaker of: Native in SpanishSpanish
Login to enter a peer comment (or grade)




Return to KudoZ list


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also:



Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search