English term or phrase: N.O. / N.C. / forced-guided
optional interface module with 3 N.O. and 1 N.C. forced-guided contacts
Claudia Calvosa
Local time: 06:04
Spanish translation:Contacto N.O. ...
Explanation:
Módulo opcional de interfase con 3 contactos N.O. (Normally Open) y 1 contacto N.C. (Normally Closed) de dirección forzada.

(• Forced-Guidance means:
• The contacts in a contact set (at least 1 N.O. contact and 1 N.C. contact) must be mechanically linked together, so that it is impossible for N.O. and N.C. contacts to be closed at the same time. Also, 0.5mm minimum air gap between open contacts must be present over the whole service life, even in case of failure. The forced-guidance must always be preserved, even when a relay component fails to function correctly.
• Classes of forced-guidance:
• Class A - Relays with mutually linked contacts which form a forced-guidance contact set. A contact is considered to be open when its contact gap is >0.5mm.
• Class B – Relays with individually linked contacts, which contain a number of forced-guided contacts and other non-forced-guided contacts or changeover contacts.
• Only N.O. and N.C. contacts can be used as forced-guided contacts. Contacts, which are designed as changeover contacts, must be used as either N.O. or N.C. contacts in the sense of forced-guided operation. If the unused contact is connected to a non-safety circuit, then circuit analyses must be performed to ensure that this will not impair safety.)
Selected response from:

aschewe
Uruguay
Local time: 06:04
Grading comment
thank-you very much
4 KudoZ points were awarded for this answer



Summary of answers provided
4 +3N.O = normally open (normalmente abierto) N.C=normally closed (normalmente cerrad)
Miriam Busaniche
53 contactos de guía forzada normalmente abietos y
mónica alfonso
4Contacto N.O. ...
aschewe


  

Answers


27 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +3
N.O = normally open (normalmente abierto) N.C=normally closed (normalmente cerrad)


Explanation:
Hace referencia a contactos cuya posición normal es abierta o cerrada.

Miriam Busaniche
Local time: 06:04
Native speaker of: Spanish

Peer comments on this answer (and responses from the answerer)
agree  pzulaica
13 mins

agree  Susana Cahill
21 mins

agree  Ana Romero
19 hrs
Login to enter a peer comment (or grade)

57 mins   confidence: Answerer confidence 5/5
3 contactos de guía forzada normalmente abietos y


Explanation:
1 contacto de guía forzada normalmente cerrado
HIH

mónica alfonso
Local time: 06:04
Native speaker of: Spanish
PRO pts in pair: 1657
Login to enter a peer comment (or grade)

1 hr   confidence: Answerer confidence 4/5Answerer confidence 4/5
Contacto N.O. ...


Explanation:
Módulo opcional de interfase con 3 contactos N.O. (Normally Open) y 1 contacto N.C. (Normally Closed) de dirección forzada.

(• Forced-Guidance means:
• The contacts in a contact set (at least 1 N.O. contact and 1 N.C. contact) must be mechanically linked together, so that it is impossible for N.O. and N.C. contacts to be closed at the same time. Also, 0.5mm minimum air gap between open contacts must be present over the whole service life, even in case of failure. The forced-guidance must always be preserved, even when a relay component fails to function correctly.
• Classes of forced-guidance:
• Class A - Relays with mutually linked contacts which form a forced-guidance contact set. A contact is considered to be open when its contact gap is >0.5mm.
• Class B – Relays with individually linked contacts, which contain a number of forced-guided contacts and other non-forced-guided contacts or changeover contacts.
• Only N.O. and N.C. contacts can be used as forced-guided contacts. Contacts, which are designed as changeover contacts, must be used as either N.O. or N.C. contacts in the sense of forced-guided operation. If the unused contact is connected to a non-safety circuit, then circuit analyses must be performed to ensure that this will not impair safety.)



    Reference: http://www.fornvalls.com/fornvalls/pdfs/azr.pdf
aschewe
Uruguay
Local time: 06:04
Native speaker of: Spanish
PRO pts in pair: 48
Grading comment
thank-you very much
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search