tension d'essai de choc

English translation: surge test voltage


Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
French term or phrase:tension d\'essai de choc
English translation:surge test voltage
Entered by: Daniel Weston
Options:
- Contribute to this entry
- Include in personal glossary

21:59 Dec 16, 2011
French to English translations [PRO]
Tech/Engineering - Energy / Power Generation
French term or phrase: tension d'essai de choc
Here is the entire sentence:

"Les enroulements de transformateur isolés pour une **tension d’essai de choc** 650 kVcrête et d’essai à fréquence industrielle 275 kVeff et plus, peuvent avoir une isolation graduée."

Would this be considered an "impact voltage"?
Daniel Weston
United States
impulse test voltage
Explanation:
Check these bilingual sites:
http://webstore.iec.ch/preview/info_iec61800-5-1{ed2.0}b.pdf

Check Tableau 19 and Table 19

And this:

http://www.nostop.cn/1com1net/webeditor/UploadFile/200922717...
At Table 6 and Tableau 6
Selected response from:

Marco Solinas
Local time: 00:52
Grading comment
Thanks
4 KudoZ points were awarded for this answer



Summary of answers provided
2 +4impulse test voltageMarco Solinas
4 -2voltage test for shock
narasimha CSN MURTHY


Discussion entries: 3





  

Answers


2 hrs   confidence: Answerer confidence 2/5Answerer confidence 2/5 peer agreement (net): +4
impulse test voltage


Explanation:
Check these bilingual sites:
http://webstore.iec.ch/preview/info_iec61800-5-1{ed2.0}b.pdf

Check Tableau 19 and Table 19

And this:

http://www.nostop.cn/1com1net/webeditor/UploadFile/200922717...
At Table 6 and Tableau 6

Marco Solinas
Local time: 00:52
Specializes in field
Native speaker of: Native in EnglishEnglish, Native in ItalianItalian
PRO pts in category: 4
Grading comment
Thanks

Peer comments on this answer (and responses from the answerer)
agree  Tony M: Seems conclusive! (I think that last link is actually in breach of IEC terms!) / Oh, the comment from rk is interesting, as 'surge test voltage' is in fact the answer I'd originally submitted but then hid when I saw Marco's answer.
11 mins

agree  meirs: Of course
6 hrs

agree  chris collister
8 hrs

agree  rkillings: Or 'surge test voltage', in practice.
22 hrs
Login to enter a peer comment (or grade)

5 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): -2
tension d\'essai de choc
voltage test for shock


Explanation:
The windings of the transformer insulated for a **voltage test for shock**650 kV peak and test at industrial frequency 275 kV actual and more, can have a graduated insulation.

narasimha CSN MURTHY
India
Local time: 13:22
Specializes in field
Native speaker of: Native in EnglishEnglish
PRO pts in category: 27

Peer comments on this answer (and responses from the answerer)
disagree  meirs: impulse is the term - see BIL = Basic Impulse Level
4 hrs

disagree  Tony M: Not the correct term in this context.
5 hrs