Drahtbruchwiderstand

English translation: continuity test/verification resistor/resistance


Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
German term or phrase:Drahtbruchwiderstand
English translation:continuity test/verification resistor/resistance
Entered by: Claire Cox
Options:
- Contribute to this entry
- Include in personal glossary

13:06 Aug 11, 2008
German to English translations [PRO]
Tech/Engineering - Electronics / Elect Eng / Instrumentation & control
German term or phrase: Drahtbruchwiderstand
From a training manual on signal acquisition:

Folgende Anwendungen können bei Binäreingaben typischerweise parametriert werden:

Wechsler ohne Drahtbruchwiderstand
Einfachkontakt mit Drahtbruchwiderstand
Einfachkontakt ohne Drahtbruchwiderstand

Many thanks for any guidance!
Claire Cox
Local time: 13:51
continuity test/verification resistor/resistance
Explanation:
With a device like the conductivity-based level detectors described in the first reference cited below, a continuity-test or continuity verification resistor (with a corresponding resistance) may be desirable to provide protection against an open circuit fault condition (Drahtbruch), since the resistance measured or shown by the device can be practically infinite under certain operating conditions and it may be important to be able to distinguish this operational state from an open-circuit (abnormal) condition. With a continuity test resistor, the upper limit of the resistance seen under normal conditions is set by the resistor and a significantly higher (i.e. infinite) resistance indicates an open-circuit fault.

text from second ref:

Mit der Einstellung Drahtbrucherkennung wird in einem Messzyklus von kleiner 0,5sec überprüft, ob ein Drahtbruchwiderstand am Kanal angeschlossen ist.
Der verwendete Widerstand sollte typisch 50 ... 470kOhm betragen.
Sobald ein Kanal mit Drahtbrucherkennung aktiviert ist, so ist die Ausgangslogik zu allen Kanälen invertiert, also bei LEER schaltend.
Ist die Drahtbruchprüfung nicht erfolgreich, d.h. der Draht ist gebrochen, so fallen alle Ausgänge des Geräts ab.
Das Relais R2 ist für die Drahtbrucherkennung fest vorgesehen. Es kann kein anderer Ausgang für diesen Zweck eingestellt werden.
Jeder Kanal kann einzeln auf Drahtbruch eingestellt werden, aber das Drahtbruchsignal ist immer R2.
Ist Drahtbruch einmal aktiviert so kann keiner der Kanäle auf R2 zugreifen.

--------------------------------------------------
Note added at 3 hrs (2008-08-11 16:53:29 GMT)
--------------------------------------------------

To be fair, 'continuity test' and 'continuity verification' don't google especially well in this context, although this is the purpose of the resistor in this case. You might consider using 'terminating resistor' (perhaps with the additional information 'for continuity verification').
Selected response from:

Ken Cox
Local time: 14:51
Grading comment
Thanks to all who contributed
4 KudoZ points were awarded for this answer



Summary of answers provided
4continuity test/verification resistor/resistanceKen Cox
3 +1open-circuit resistor
Kim Metzger
2wire break resistance
Manuela Junghans


Discussion entries: 2





  

Answers


21 mins   confidence: Answerer confidence 2/5Answerer confidence 2/5
wire break resistance


Explanation:
https://www.alliedelec.com/Search/ProductDetail.aspx?SKU=501...

Manuela Junghans
United Kingdom
Local time: 13:51
Specializes in field
Native speaker of: Native in GermanGerman
PRO pts in category: 38
Login to enter a peer comment (or grade)

45 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): +1
open-circuit resistor


Explanation:
Hi Claire - the reason I asked about Siemens is I'm not an expert in electronics and didn't want to suggest something from a dictionary you might already have. For Drahtbruch, Siemens gives wire breakage and open circuit. Drahtbruch-Kontrollwiderstand is line continuity supervisory resistor.

--------------------------------------------------
Note added at 47 mins (2008-08-11 13:54:04 GMT)
--------------------------------------------------

VLF Receiver Calibration using Thermal NoiseIt may be time consuming to visit the front end, or a signal generator capable ... The mean square noise voltage present across the open-circuit resistor is ...
www.abelian.demon.co.uk/vlf/calib.html



    Fachwörterbuch industrielle Elektrotechnik - Siemens
Kim Metzger
Mexico
Local time: 07:51
Native speaker of: Native in EnglishEnglish
PRO pts in category: 210

Peer comments on this answer (and responses from the answerer)
agree  Erika Berrai-Flynn: siehe auch: http://deu.proz.com/kudoz/german_to_english/telecommunicatio...
1 day2 hrs
Login to enter a peer comment (or grade)

3 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
continuity test/verification resistor/resistance


Explanation:
With a device like the conductivity-based level detectors described in the first reference cited below, a continuity-test or continuity verification resistor (with a corresponding resistance) may be desirable to provide protection against an open circuit fault condition (Drahtbruch), since the resistance measured or shown by the device can be practically infinite under certain operating conditions and it may be important to be able to distinguish this operational state from an open-circuit (abnormal) condition. With a continuity test resistor, the upper limit of the resistance seen under normal conditions is set by the resistor and a significantly higher (i.e. infinite) resistance indicates an open-circuit fault.

text from second ref:

Mit der Einstellung Drahtbrucherkennung wird in einem Messzyklus von kleiner 0,5sec überprüft, ob ein Drahtbruchwiderstand am Kanal angeschlossen ist.
Der verwendete Widerstand sollte typisch 50 ... 470kOhm betragen.
Sobald ein Kanal mit Drahtbrucherkennung aktiviert ist, so ist die Ausgangslogik zu allen Kanälen invertiert, also bei LEER schaltend.
Ist die Drahtbruchprüfung nicht erfolgreich, d.h. der Draht ist gebrochen, so fallen alle Ausgänge des Geräts ab.
Das Relais R2 ist für die Drahtbrucherkennung fest vorgesehen. Es kann kein anderer Ausgang für diesen Zweck eingestellt werden.
Jeder Kanal kann einzeln auf Drahtbruch eingestellt werden, aber das Drahtbruchsignal ist immer R2.
Ist Drahtbruch einmal aktiviert so kann keiner der Kanäle auf R2 zugreifen.

--------------------------------------------------
Note added at 3 hrs (2008-08-11 16:53:29 GMT)
--------------------------------------------------

To be fair, 'continuity test' and 'continuity verification' don't google especially well in this context, although this is the purpose of the resistor in this case. You might consider using 'terminating resistor' (perhaps with the additional information 'for continuity verification').


    Reference: http://www.negele.net/NVS_05zoll_hyg.pdf
    Reference: http://www.seli.de/downloads/Bedienungsanleitung%20SNG.pdf
Ken Cox
Local time: 14:51
Specializes in field
Native speaker of: Native in EnglishEnglish
PRO pts in category: 723
Grading comment
Thanks to all who contributed