Stauchverhalten

English translation: buckling behaviour


Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
German term or phrase:Stauchverhalten
English translation:buckling behaviour
Entered by: babbelbekkie
Options:
- Contribute to this entry
- Include in personal glossary

20:06 Dec 7, 2011
German to English translations [PRO]
Tech/Engineering - Engineering (general) / Medical engineering
German term or phrase: Stauchverhalten
Stauchverhalten und Flächenpressung nach beschleunigter Alterung (3 Jahre)

Es wird an jedem Testprodukt eine Stauchmessung durchgeführt.

Gestauchter Tip-Bereich

Hi everybody

My question concerns the use of "Stauch*/Stauchen" in this case, in various combinations, such as Stauchverhalten, Stauchmessung, Stauchkraft, gestaucht etc. "Compression" is of course the first guess and the suggestion of many dictionaries, but am not entirely sure about it.

My problem is that nothing is actually "compressed" in the way I understood it hitherto. Wikipedia defines Compression as "Physical compression is the result of the subjection of a material to compressive stress, which results in reduction of volume as compared to an uncompressed but otherwise identical state", which sort of roughly matches my understanding. But in this case, no reduction of volume takes place. But then again, Wikipedia also says "In simple terms, compression is a pushing force", so it might fit after all.

The setup described is as follows: A catheter is placed in a transparent plastic tube, with the top end of the catheter clamped in a testing device and the other end resting on a plate. The tube is shorter than the catheter, so part of the catheter protrudes at the bottom. The clamped end is then moved down and the contact force on the plate measured, until the tip slips off the plate. The catheter is straight at the beginning, then it starts to curve to compensate for the shorter distance between clamped end and other end, until it sometimes sort of forms a loop. And that "curving" of the catheter in the protruding part (it cannot curve as much inside the tube) is what is called the "Gestauchter Tip-Bereich" in the source text. The force applied to achieve this curving is called the Stauchkraft.

Can anybody here confirm whether "compression" is also OK for this meaning? If not, what would you call this "Stauchung" instead?

Thanks in advance for any ideas!
babbelbekkie
Local time: 04:08
buckling behaviour
Explanation:
I think it's rather compression than buckling what causes looping of the catheter tip.

With its cutting edge design, the ASAP catheter is intended to save you time by ensuring maximized clot aspiration, offering a significant kink and buckle resistant catheter to navigate tortuous anatomy, and providing the convenience of an all inclusive accessory kit and tray.
http://www.merit.com/products/media.aspx?type=video&id=27535...

A catheter advanced to this portion may not follow the guidewire when it is retracted and cause the guide wire to buckle into a loop. The catheter may then drag along the inside of vessel and catch on the guide catheter tip.
:
Wenn der Katheter bis in diesen Bereich vorangeschoben wurde, folgt er möglicherweise dem Führungsdraht nicht, wenn er zurückgezogen wird, und bewirkt, dass der Führungsdraht eine Schleife bildet. Der Katheter kann dann an der Gefäßinnenseite entlangschleifen und sich an der Spitze des Führungskatheters verfangen.
http://www.volcanocorp.com/products/805007-001-012-IFU-REVOL...

It has become apparent that the unfavourable buckling behaviour of the known catheter is due to the asymmetrical cross-section of the basic body.
With the catheter according to the invention the buckling behaviour is only defined by the basic body. The separate tube-like body lies more or less free inside the lumen of the basic body and does not influence the buckling behaviour. Consequently the catheter according to the invention has a constant bending stiffness in all directions which is conducive to the prevention of buckling behaviour.
http://ip.com/patent/EP0693295B1
Selected response from:

Johannes Gleim
Local time: 04:08
Grading comment
That sounds more like it, thanks a lot, also for the reference links.
4 KudoZ points were awarded for this answer



Summary of answers provided
3buckling behaviour
Johannes Gleim


  

Answers


1 hr   confidence: Answerer confidence 3/5Answerer confidence 3/5
buckling behaviour


Explanation:
I think it's rather compression than buckling what causes looping of the catheter tip.

With its cutting edge design, the ASAP catheter is intended to save you time by ensuring maximized clot aspiration, offering a significant kink and buckle resistant catheter to navigate tortuous anatomy, and providing the convenience of an all inclusive accessory kit and tray.
http://www.merit.com/products/media.aspx?type=video&id=27535...

A catheter advanced to this portion may not follow the guidewire when it is retracted and cause the guide wire to buckle into a loop. The catheter may then drag along the inside of vessel and catch on the guide catheter tip.
:
Wenn der Katheter bis in diesen Bereich vorangeschoben wurde, folgt er möglicherweise dem Führungsdraht nicht, wenn er zurückgezogen wird, und bewirkt, dass der Führungsdraht eine Schleife bildet. Der Katheter kann dann an der Gefäßinnenseite entlangschleifen und sich an der Spitze des Führungskatheters verfangen.
http://www.volcanocorp.com/products/805007-001-012-IFU-REVOL...

It has become apparent that the unfavourable buckling behaviour of the known catheter is due to the asymmetrical cross-section of the basic body.
With the catheter according to the invention the buckling behaviour is only defined by the basic body. The separate tube-like body lies more or less free inside the lumen of the basic body and does not influence the buckling behaviour. Consequently the catheter according to the invention has a constant bending stiffness in all directions which is conducive to the prevention of buckling behaviour.
http://ip.com/patent/EP0693295B1

Johannes Gleim
Local time: 04:08
Specializes in field
Native speaker of: Native in GermanGerman
PRO pts in category: 99
Grading comment
That sounds more like it, thanks a lot, also for the reference links.
Login to enter a peer comment (or grade)




Return to KudoZ list


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also: