Italian term or phrase:contatto di on/off pulito
French translation:contact sans potentiel marche /arrêt
Entered by: elysee
Options:
- Contribute to this entry
- Include in personal glossary

14:32 Aug 30, 2010
Italian to French translations [PRO]
Tech/Engineering - Energy / Power Generation / alimentazione industriale
Italian term or phrase: contatto di on/off pulito
Tratto da un catalogo di alimentazione industriale, ecco la citazione:
"(Vi è un) ampio range di regolazione lineare e la possibilità di spegnere il vibratore durante il normale funzionamento, usando un contatto di on/off pulito oppure in tensione (0-24 vdc)".
è principalmente quel "pulito" che non riesco a tradurre...grazie
Lara87
Austria
Local time: 15:24
contact sans potentiel marche /arrêt
Explanation:
nel tuo contesto vuole dire un contatto senza la corrente effettiva oppure a basso voltaggio come infatti è indicato poi nella tua frase (24V)

contact sans potentiel
(sans puissance / sans courant)


usando un contatto di on/off pulito oppure in tensione (0-24 vdc)
= en utilisant un contact sans potentiel marche /arrêt ou sous tension (0-24 vdc)

--------------------------------------------------
Note added at 57 mins (2010-08-30 15:29:07 GMT)
--------------------------------------------------

10080_2.2 Thermostat P_bea
...de service, avec contact inverseur sans potentiel. Une sortie de minuteur à part ... Marche. Arrêt. Température de la pièce X i course Y [%] ...
http://www.heimeier.com/fr/PDF/Info_french/2200-04-483-00-03...


--------------------------------------------------
Note added at 58 mins (2010-08-30 15:30:34 GMT)
--------------------------------------------------

Système de commande de compresseur SIGMA CONTROL
...entrée de signaux pour MARCHE/ARRÊT à distance ... défaut général, moteur en marche; contacts sans potentiel réglables par l'utilisateur en alternative:...
http://be.fr.kaeser.com/Images/P-780-FR-tcm62-6777.pdf

Arrêt. Canal A (1 canal). Entraînements ext. Marche. Canal B (1 canal). Entraînements MAR-. 42. A cette entrée, un contact sans potentiel (rupteur) peut ...
http://supportwop.com/client/images/doc_wop/raccordement_X11...


--------------------------------------------------
Note added at 20 days (2010-09-19 23:02:45 GMT) Post-grading
--------------------------------------------------

merci
Selected response from:

elysee
Italy
Local time: 15:24
Grading comment
Merci beaucoup!
4 KudoZ points were awarded for this answer



Summary of answers provided
4 +1contact sans potentiel marche /arrêt
elysee
4contact secDimitri Strappazzon
Summary of reference entries provided
Françoise Vogel

  

Answers


20 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
contact sec


Explanation:
Molto utilizzato nel mondo dell'automazione

Dimitri Strappazzon
Local time: 15:24
Works in field
Native speaker of: Native in FrenchFrench, Native in ItalianItalian
Login to enter a peer comment (or grade)

55 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +1
contact sans potentiel marche /arrêt


Explanation:
nel tuo contesto vuole dire un contatto senza la corrente effettiva oppure a basso voltaggio come infatti è indicato poi nella tua frase (24V)

contact sans potentiel
(sans puissance / sans courant)


usando un contatto di on/off pulito oppure in tensione (0-24 vdc)
= en utilisant un contact sans potentiel marche /arrêt ou sous tension (0-24 vdc)

--------------------------------------------------
Note added at 57 mins (2010-08-30 15:29:07 GMT)
--------------------------------------------------

10080_2.2 Thermostat P_bea
...de service, avec contact inverseur sans potentiel. Une sortie de minuteur à part ... Marche. Arrêt. Température de la pièce X i course Y [%] ...
http://www.heimeier.com/fr/PDF/Info_french/2200-04-483-00-03...


--------------------------------------------------
Note added at 58 mins (2010-08-30 15:30:34 GMT)
--------------------------------------------------

Système de commande de compresseur SIGMA CONTROL
...entrée de signaux pour MARCHE/ARRÊT à distance ... défaut général, moteur en marche; contacts sans potentiel réglables par l'utilisateur en alternative:...
http://be.fr.kaeser.com/Images/P-780-FR-tcm62-6777.pdf

Arrêt. Canal A (1 canal). Entraînements ext. Marche. Canal B (1 canal). Entraînements MAR-. 42. A cette entrée, un contact sans potentiel (rupteur) peut ...
http://supportwop.com/client/images/doc_wop/raccordement_X11...


--------------------------------------------------
Note added at 20 days (2010-09-19 23:02:45 GMT) Post-grading
--------------------------------------------------

merci

elysee
Italy
Local time: 15:24
Native speaker of: Native in FrenchFrench
PRO pts in category: 11
Grading comment
Merci beaucoup!

Peer comments on this answer (and responses from the answerer)
agree  Francine Alloncle: Bravo comme toujours !
31 mins
  -> merci Francine, bonne soirée
Login to enter a peer comment (or grade)




Reference comments






Voters for reclassification
as
PRO / non-PRO
Non-PRO (1): Françoise Vogel


Return to KudoZ list


Changes made by editors
Sep 19, 2010 - Changes made by elysee:
Created KOG entryKudoZ term => KOG term


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also: