KudoZ home » Polish to English » Construction / Civil Engineering

układ pozytyw vs mijankowy

English translation: positive (position) vs. staggered joints

Advertisement

Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs
(or are passionate about them). Participation is free and the site has a strict confidentiality policy.
GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
Polish term or phrase:układ pozytyw vs mijankowy
English translation:positive (position) vs. staggered joints
Entered by: bARBARA Marszalek
Options:
- Contribute to this entry
- Include in personal glossary

18:49 Mar 9, 2007
Polish to English translations [PRO]
Tech/Engineering - Construction / Civil Engineering / construction technology
Polish term or phrase: układ pozytyw vs mijankowy
zaprojektowano blachę trapezową wysokości 150mm w układzie pozytyw jednoprzęsłowym lub dwuprzęsłowym mijankowym.
bARBARA Marszalek
Local time: 22:38
positive (position) vs. staggered joints
Explanation:
staggered joints było kilka dni temu
http://tinyurl.com/25wxzv

--------------------------------------------------
Note added at 2 hrs (2007-03-09 21:03:30 GMT) Post-grading
--------------------------------------------------

żev=byś nie musiala grebać:
The minimum and maximum values for kII for standard trapezoidal metal plate covering were evaluated in table 2. Thereby min kII are valid for positive position (= broad flange up) and max kII for negative position (= broad flange down) of the trapezoidal sections
Selected response from:

bartek
Local time: 22:38
Grading comment
ok, dzięki, to rozumiem, że układ negatyw (negative)
4 KudoZ points were awarded for this answer

Advertisement


Summary of answers provided
4positive (position) vs. staggered joints
bartek


Discussion entries: 2





  

Answers


1 hr   confidence: Answerer confidence 4/5Answerer confidence 4/5
positive (position) vs. staggered joints


Explanation:
staggered joints było kilka dni temu
http://tinyurl.com/25wxzv

--------------------------------------------------
Note added at 2 hrs (2007-03-09 21:03:30 GMT) Post-grading
--------------------------------------------------

żev=byś nie musiala grebać:
The minimum and maximum values for kII for standard trapezoidal metal plate covering were evaluated in table 2. Thereby min kII are valid for positive position (= broad flange up) and max kII for negative position (= broad flange down) of the trapezoidal sections

bartek
Local time: 22:38
Works in field
Native speaker of: Polish
PRO pts in category: 2328
Grading comment
ok, dzięki, to rozumiem, że układ negatyw (negative)