Login or register (free and only takes a few minutes) to participate in this question.You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.
Serbo-Croat to English translations [PRO] Tech/Engineering - Electronics / Elect Eng | | Serbo-Croat term or phrase: slučajni napon dodira | | Opasna mesta (razvodni ormani i provodnici pod naponom) moraju biti propisno obeleženi i zaštićeni od mehaničkih oštećenja. Sve elektro instalcije u pogonima i osvetljenja moraju biti izvedene u skladu sa tehničkim propisima i standardom. Sva orudja i uredjaji za rad moraju biti uzemljeni i zaštićeni od slučajnog napona dodira i periodično ispitani u zakonski predvidjenim rokovima. Svaki rad pod naponom je zabranjen. |
| bpetrovKudoZ activityQuestions: 3398 ( 1 open) ( 5 without valid answers) ( 63 closed without grading) Answers: 262 Serbia
| Local time: 09:22
|
| | accidental/unintentional touch voltage | Explanation: „Grounding and Bonding Book
...
Touch Voltage - The IEEE definition of touch voltage is "the potential (voltage) difference between a bonded metallic structure and a point on the earth 3 ft from the structure."
( http://mikeholt.com/mojonewsarchive/GB-HTML/HTML/Grounding-P... )
JUS - GLAVNA TABELA:
Napon dodira - Touch voltage (EN 60519-3, Clause 0.4., p. 19)
„Zaštita na gradilištima od udara električne struje
...
- Dodirni napon (touch voltage, Beruhrüngsspannung),
napon koji se pojavljuje zbog kvara u izolaciji, između istodobno dodirljivih dijelova.
- Dogovorena granica dodirnog napona (oznaka UL)
(conventional touch voltage limit (symbol UL), Vereinbarte Grenze der Berührungsspannung (UL)),
najveća vrijednost dodirnog napona koja se može održati neograničeno vrijeme pri utvrđenim uvjetima vanjskih utjecaja.“
( http://64.233.183.104/search?q=cache:uuBTGNyQcdoJ:hrcak.srce...|lang_sr|lang_sl )
„IEEE Xplore - Methods for protecting employees and others from electrical hazards adjacent to electric utility vehicles
...
potential zone around the vehicle, reducing step. and touch voltage hazards to workers. 3) Accidental contact will create a audible and visual ...“
( http://ieeexplore.ieee.org/Xplore/login.jsp?url=/iel3/61/903... )
„SAUDI STANDARD
...
The conventional touch voltage limit as defined in SASO 1613 for the purpose of automatic disconnection of the supply is not within the scope of this report.
...
A.2 Touchable parts
* Touch area (fingertip, finger, hand)
* Grippability
Location of the touchable part
Intentional/unintentional touch“
( https://www.saso.org.sa/prj/E3562.pdf |
| Selected response from:
 Vesna Stankovic Local time: 09:22
| Grading comment Hvala! 4 KudoZ points were awarded for this answer |
| |
| Discussion entries: 0 |
|---|
Automatic update in 00:
|
2 hrs confidence: peer agreement (net): +3 accidental/unintentional touch voltage
Explanation: „Grounding and Bonding Book
...
Touch Voltage - The IEEE definition of touch voltage is "the potential (voltage) difference between a bonded metallic structure and a point on the earth 3 ft from the structure."
( http://mikeholt.com/mojonewsarchive/GB-HTML/HTML/Grounding-P... )
JUS - GLAVNA TABELA:
Napon dodira - Touch voltage (EN 60519-3, Clause 0.4., p. 19)
„Zaštita na gradilištima od udara električne struje
...
- Dodirni napon (touch voltage, Beruhrüngsspannung),
napon koji se pojavljuje zbog kvara u izolaciji, između istodobno dodirljivih dijelova.
- Dogovorena granica dodirnog napona (oznaka UL)
(conventional touch voltage limit (symbol UL), Vereinbarte Grenze der Berührungsspannung (UL)),
najveća vrijednost dodirnog napona koja se može održati neograničeno vrijeme pri utvrđenim uvjetima vanjskih utjecaja.“
( http://64.233.183.104/search?q=cache:uuBTGNyQcdoJ:hrcak.srce...|lang_sr|lang_sl )
„IEEE Xplore - Methods for protecting employees and others from electrical hazards adjacent to electric utility vehicles
...
potential zone around the vehicle, reducing step. and touch voltage hazards to workers. 3) Accidental contact will create a audible and visual ...“
( http://ieeexplore.ieee.org/Xplore/login.jsp?url=/iel3/61/903... )
„SAUDI STANDARD
...
The conventional touch voltage limit as defined in SASO 1613 for the purpose of automatic disconnection of the supply is not within the scope of this report.
...
A.2 Touchable parts
* Touch area (fingertip, finger, hand)
* Grippability
Location of the touchable part
Intentional/unintentional touch“
( https://www.saso.org.sa/prj/E3562.pdf
|  Vesna Stankovic Local time: 09:22 Specializes in field Native speaker of: Serbian, Serbo-Croat PRO pts in category: 36
|
| | | | KudoZ™ translation helpThe KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases. See also: Search millions of term translations |
| |