Spanish term or phrase:fusión de la varilla de conexión a tierra
English translation:fusing/melting of the earth rod
Entered by: Wendy Leech
Options:
- Contribute to this entry
- Include in personal glossary

09:07 Jul 6, 2011
Spanish to English translations [PRO]
Tech/Engineering - Electronics / Elect Eng / transformers/wind turbine
Spanish term or phrase: fusión de la varilla de conexión a tierra
From a report on the cuases of a fire in the nacelle of a wind turbine:

Existe un alto número de circunstancias que son incompatibles con un fallo en la zona de alta tensión del transformador:

- fusión de la varilla de conexión a tierra, que tampoco habría actuado en caso de que el transformador fuese la causa del siniestro.


also

Se encontró fundida la varilla de conexión a tierra, lo que nunca habría ocurrido si la causa hubiera sido en la Alta Tensión del transformador

I am looking for the correct term for fusion/fundida - i.e. what do Earth Rods do when they fail (do they "blow" like a fuse?).

Thanks.
Wendy Leech
United Kingdom
Local time: 02:58
fusing/melting of the earth rod
Explanation:
http://www.openelectrical.org/wiki/index.php?title=Earthing_...
"the temperature limit for earthing grid conductors is the melting point of the conductor. In other words, during the worst case earth fault, we don't want the earthing grid conductors to start melting!"

http://www.erico.com/public/library/fep/LT0359_2.pdf
"Where higher fault conditions exist, the conductor size is determined by considering the circumstances required to avoid fusing (melting) the conductor."

http://www.radiobanter.com/showthread.php?t=121846&page=2
"A lighning down conductor needs to carry something like 20kA for 100ms, so it needs to be substantial enough that it doesn't melt and remains in place to protect against the next strike."
Selected response from:

Fiona Kirton
United Kingdom
Local time: 02:58
Grading comment
Thanks.
4 KudoZ points were awarded for this answer



Summary of answers provided
3 +1fusing/melting of the earth rod
Fiona Kirton


  

Answers


26 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): +1
fusing/melting of the earth rod


Explanation:
http://www.openelectrical.org/wiki/index.php?title=Earthing_...
"the temperature limit for earthing grid conductors is the melting point of the conductor. In other words, during the worst case earth fault, we don't want the earthing grid conductors to start melting!"

http://www.erico.com/public/library/fep/LT0359_2.pdf
"Where higher fault conditions exist, the conductor size is determined by considering the circumstances required to avoid fusing (melting) the conductor."

http://www.radiobanter.com/showthread.php?t=121846&page=2
"A lighning down conductor needs to carry something like 20kA for 100ms, so it needs to be substantial enough that it doesn't melt and remains in place to protect against the next strike."

Fiona Kirton
United Kingdom
Local time: 02:58
Native speaker of: Native in EnglishEnglish
PRO pts in category: 20
Grading comment
Thanks.

Peer comments on this answer (and responses from the answerer)
agree  psicutrinius
7 hrs
Login to enter a peer comment (or grade)




Return to KudoZ list


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also: