English translation: seguridad intrínsica > intrinsic safety
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.
Spanish to English translations [PRO] Tech/Engineering - Electronics / Elect Eng / Cabling
Spanish term or phrase:S.I. (not Sisteme Internacionale)
Morning all,
Spanish Spanish to UK English
This is from a section talking about the labelling system for the cables of a large engineering project. Sorry no more context.
681-MC-EI-002 Multicable 002 de señales analógicas de alto nivel de S.I. del anexo 681
445-MC-DI-034 Multicable 034 de señales digitales de bajo nivel de S.I. del anexo 445
-------------------------------------------------- Note added at 5 mins (2011-11-17 09:57:20 GMT) --------------------------------------------------
=
intrinsically safe
PHOENIX CONTACT | Pluggable Intrinsic Safety Barriers www.phoenixcontact.com/signal-level-matching/31248_35025.ht...
Jump to Analog In: Feeds intrinsically safe 2- or 3-conductor measuring transducers installed in an Ex area and transmits the 4-20 mA signal to a load in a ...
-------------------------------------------------- Note added at 6 mins (2011-11-17 09:58:38 GMT) --------------------------------------------------
or even
intrinsic safety
Intrinsically Safe Solutions Receive Marine-type Approvals www.pepperl-fuchs.us/usa/en/16373.htm
K-System intrinsic safety barriers are a complete range of products designed for discrete or analog signals. K-System intrinsic safety barriers carry all major ...
-------------------------------------------------- Note added at 3 hrs (2011-11-17 13:12:23 GMT) --------------------------------------------------
Explosion-Proof Pressure Transmitter | Non-Incendive Pressure ... www.astsensors.com/application/pressure/ex-pressure-transmi...
... locations, including explosion-proof, non-incendive and intrinsically safe areas. ... currently support explosion-proof requirements for the Energy, Oil and Gas industries. ... These products will need conduit installed over the cable or into the ... Well Optimization / RTU / SCADA; Oil and Gas Pipelines; Drilling Platforms; CNG ...
[PDF]
The complete intrusion detection package for the oil & gas industry www.fftsecurity.com/brochures/FFT_Oil_Vertical_AU_Singles.p...
File Format: PDF/Adobe Acrobat
Buried oil and gas pipelines. 4. Finally, you no longer ... to be installed in the field, are intrinsically safe ... cable is intrinsically safe and not affected by RFI, EMI, ...
Sales services www.iskrazascite.si/index.php/en/company/sales-services
Special applications (gas conduit, pipeline, intrinsic safety,…) In last 10 years we became specialists in solving problems of overvoltages/transient surges in ...
-------------------------------------------------- Note added at 3 hrs (2011-11-17 13:14:21 GMT) --------------------------------------------------
Convertidor de señal universal, con seguridad intrínseca para la ...
cmswebdav.weidmueller.de/...senales.../12035200... - Translate this page
File Format: PDF/Adobe Acrobat - Quick View
Amplificador separador NAMUR. • Convierte señales digitales con seguridad intrínseca (NAMUR / contacto de conmutación) de zonas EX zona 0 en señales ...
-------------------------------------------------- Note added at 5 days (2011-11-22 10:01:04 GMT) Post-grading --------------------------------------------------
I should have mentinoed this earlier, but th eoverall project is a gas pipeline and so although general security is important that of data transfer wouldn't be (would it?) as the only data transferred is to open valves, pressure readings, etc....
The documents are split bewteen different translators....
I think that Charles' suggestion seems logical and to fit well with all previous context, although it is hard to decide as "signal integrity" also works well and the doc often uses English abbreviations.... ho hum.
...to anexo 681 or anexo 445? They might give us some pointers.. I agree with Charles that intrinsic safety (sparks, explosions, shortcircuits, etc) probably isn't much of an issue with this kind of wiring, although information security would be.
Automatic update in 00:
Answers
19 mins confidence: peer agreement (net): +1
signal integrity
Explanation: If you search for
cables "high level of S.I." "signal integrity"
there are some relevant results - for cables, this seems a reasonable option - not all acronyms are translated into Spanish, as we know.
Lanna Rustage Local time: 03:59 Works in field Native speaker of: English PRO pts in category: 34
Explanation: Since it's talking about cables, I think "S.I." is very probably "seguridad informática".
-------------------------------------------------- Note added at 27 mins (2011-11-17 10:19:28 GMT) --------------------------------------------------
After all, "multicables" with "señales analógicas" or "digitales" evidently refers to cables for data transmission. I don't think intrinsic safety (which refers to the risk of explosion or ignition) is really an issue here, but information security certainly would be.
It's also difficult to understand how the level of intrinsic safety could be different for digital and analogue.
-------------------------------------------------- Note added at 46 mins (2011-11-17 10:39:01 GMT) --------------------------------------------------
I admit this is a special case, but here is "seguridad informática" applied to cables:
"Cableado de Alto Nivel de Seguridad
Son cableados de redes que se recomiendan para instalaciones con grado de seguridad militar. El objetivo es impedir la posibilidad de infiltraciones y monitoreos de la información que circula por el cable. Consta de un sistema de tubos (herméticamente cerrados) por cuyo interior circula aire a presión y el cable. A lo largo de la tubería hay sensores conectados a una computadora. Si se detecta algún tipo de variación de presión se dispara un sistema de alarma." http://www.segu-info.com.ar/fisica/instalacioneselectricas.h...
Charles Davis Local time: 03:59 Native speaker of: English PRO pts in category: 23
-------------------------------------------------- Note added at 5 mins (2011-11-17 09:57:20 GMT) --------------------------------------------------
=
intrinsically safe
PHOENIX CONTACT | Pluggable Intrinsic Safety Barriers www.phoenixcontact.com/signal-level-matching/31248_35025.ht...
Jump to Analog In: Feeds intrinsically safe 2- or 3-conductor measuring transducers installed in an Ex area and transmits the 4-20 mA signal to a load in a ...
-------------------------------------------------- Note added at 6 mins (2011-11-17 09:58:38 GMT) --------------------------------------------------
or even
intrinsic safety
Intrinsically Safe Solutions Receive Marine-type Approvals www.pepperl-fuchs.us/usa/en/16373.htm
K-System intrinsic safety barriers are a complete range of products designed for discrete or analog signals. K-System intrinsic safety barriers carry all major ...
-------------------------------------------------- Note added at 3 hrs (2011-11-17 13:12:23 GMT) --------------------------------------------------
Explosion-Proof Pressure Transmitter | Non-Incendive Pressure ... www.astsensors.com/application/pressure/ex-pressure-transmi...
... locations, including explosion-proof, non-incendive and intrinsically safe areas. ... currently support explosion-proof requirements for the Energy, Oil and Gas industries. ... These products will need conduit installed over the cable or into the ... Well Optimization / RTU / SCADA; Oil and Gas Pipelines; Drilling Platforms; CNG ...
[PDF]
The complete intrusion detection package for the oil & gas industry www.fftsecurity.com/brochures/FFT_Oil_Vertical_AU_Singles.p...
File Format: PDF/Adobe Acrobat
Buried oil and gas pipelines. 4. Finally, you no longer ... to be installed in the field, are intrinsically safe ... cable is intrinsically safe and not affected by RFI, EMI, ...
Sales services www.iskrazascite.si/index.php/en/company/sales-services
Special applications (gas conduit, pipeline, intrinsic safety,…) In last 10 years we became specialists in solving problems of overvoltages/transient surges in ...
-------------------------------------------------- Note added at 3 hrs (2011-11-17 13:14:21 GMT) --------------------------------------------------
Convertidor de señal universal, con seguridad intrínseca para la ...
cmswebdav.weidmueller.de/...senales.../12035200... - Translate this page
File Format: PDF/Adobe Acrobat - Quick View
Amplificador separador NAMUR. • Convierte señales digitales con seguridad intrínseca (NAMUR / contacto de conmutación) de zonas EX zona 0 en señales ...
-------------------------------------------------- Note added at 5 days (2011-11-22 10:01:04 GMT) Post-grading --------------------------------------------------
Thank you for your comment!
liz askew United Kingdom Local time: 02:59 Native speaker of: English PRO pts in category: 129
Grading comment
Thanks Liz, in a subsequent document it was confirmed as Intrinsic safety