10:48 Jan 24, 2012
Spanish to English translations [PRO]
Tech/Engineering - Mechanics / Mech Engineering / Box machine
Spanish term or phrase: tensión de operación
Hello. The box machine specifications include a "tensión de operación". I would have translated it directly as "operative voltage"... But the values given are in Hertz and kilowatts, not in volts. So it can't be "voltage", can it?

"Tensión de operación: trifásica, tierra 60 Hz, 1,75 KW".

TIA.
FlyHi
Local time: 10:21
English translation:Operating voltage
Explanation:
It is is actually the voltage and the values of frequency and power are given as the conditions, under which three-phase voltage is provided.

--------------------------------------------------
Note added at 4 hrs (2012-01-24 15:17:22 GMT)
--------------------------------------------------

Why, it is stated after the colon "three phase", which actually refers to voltage. And I guess that the frequency and the power referes to the grounding (tierra) only.
Selected response from:

Vitaliy Rysyuk
Ukraine
Local time: 11:21
Grading comment
Thanks, Vitaliy.
4 KudoZ points were awarded for this answer



Summary of answers provided
5 +3Operating voltage
Vitaliy Rysyuk


  

Answers


11 mins   confidence: Answerer confidence 5/5 peer agreement (net): +3
Operating voltage


Explanation:
It is is actually the voltage and the values of frequency and power are given as the conditions, under which three-phase voltage is provided.

--------------------------------------------------
Note added at 4 hrs (2012-01-24 15:17:22 GMT)
--------------------------------------------------

Why, it is stated after the colon "three phase", which actually refers to voltage. And I guess that the frequency and the power referes to the grounding (tierra) only.

Example sentence(s):
  • Operating voltage: three-phase power (50Hz) 380V ± 10%
  • 10 Rated operating voltage: three phase, 220V, 380V, 50HZ

    Reference: http://factory.dhgate.com/relays/protection-relay-xj3-g-phas...
    Reference: http://www.tradeeasy.com/supplier/693399/products/p1166616/d...
Vitaliy Rysyuk
Ukraine
Local time: 11:21
Works in field
Native speaker of: Native in UkrainianUkrainian, Native in RussianRussian
PRO pts in category: 4
Grading comment
Thanks, Vitaliy.
Notes to answerer
Asker: But the text provides no voltage... Just the frequency and the power.


Peer comments on this answer (and responses from the answerer)
agree  Beatriz Candil Garcia
5 mins
  -> Many thanks, Beatriz!

agree  psicutrinius: Well, voltage SHOULD be quoted. Seems one of those sloppy specs where some things are "taken for granted". Standard 3ph. voltage supply is 380V.
50 mins
  -> Many thanks!

agree  cranesfreak
6 hrs
  -> Many thanks!
Login to enter a peer comment (or grade)