transformador de relacion unica

21:39 May 19, 2002
Spanish to English translations [PRO]
Tech/Engineering
Spanish term or phrase: transformador de relacion unica
electrical engineering, cable landing for street lighting poles
llollypop


Summary of answers provided
4 +1fixed-ratio transformer
two2tango
4single step transformer?
Robert INGLEDEW
4single-ratio transformer
Alexandra Potts
4single-ratio transformer
Michael O' Brien
4 -1one to one transformer
Jose Alonso
4 -2transformer with ratio 1:1
Maria Luisa Duarte
2single pole transformer
Luis Rey Ballesteros (Luiroi)


  

Answers


5 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): -2
transformer with ratio 1:1


Explanation:
+

--------------------------------------------------
Note added at 2002-05-19 21:46:19 (GMT)
--------------------------------------------------

a transformer in which the primary and secondary windings have the same number of turns.

Reference Bernard J.Canceill,ingénieur-conseil en télécommunication,Paris,1994


Maria Luisa Duarte
Spain
Local time: 18:05
Native speaker of: Native in EnglishEnglish, Native in PortuguesePortuguese
PRO pts in pair: 3168

Peer comments on this answer (and responses from the answerer)
disagree  Alexandra Potts: Single-ratio transformers can have a ratio of 200:5 - see below
56 mins

disagree  two2tango: fixed does not mean 1:1
2 hrs
Login to enter a peer comment (or grade)

31 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
single step transformer?


Explanation:
I did not find transformador de relación única in Yahoo, so I am guessing. But I believe it refers to transformers that only transform frome one voltage to another (i.e. 220 V to 12 V, 380 to 330, or 13.2 V to 220 V, by way of example).
The references I am going to give might be tricky, because they are based on my assumption, and if my assumption is wrong, the references will be wrong also. Peer opinions, please.

PULIZZI ENGINEERING INC. (PDF)
... the input whereas the 0ther 6 outlets (5-15R) run through a single step up transformer.
SUC 1558: Power input 120V~ / Power output 240V~. Front panel view. SDC ...
http://www.pulizzi.com/datasheets/sdu15598.pdf
More Results From: www.pulizzi.com


MAINS PROTECTION & TRANSFORMERS
... for mobile user are the range of step down transformers that allow a product fitted ... 1+.
3+. 5+. 3963. USA to UK Transformer - Single Skt (max 30VA load), ...
http://www.videkonline.co.uk/SubSections.asp?sectionID=101
More Results From: www.videkonline.co.uk

Single step could be step up or step down, but I must repeat I am just guessing.



--------------------------------------------------
Note added at 2002-05-19 22:11:39 (GMT)
--------------------------------------------------

Sorry, there was a typo: 380 to 220 V.

Robert INGLEDEW
Argentina
Local time: 13:05
Native speaker of: Native in EnglishEnglish, Native in SpanishSpanish
PRO pts in pair: 1940
Grading comment
I believe the 1:1 ratio transformer is the correct. Thank y
Login to enter a peer comment (or grade)
The asker has declined this answer
Comment: I believe the 1:1 ratio transformer is the correct. Thank y

1 hr   confidence: Answerer confidence 4/5Answerer confidence 4/5
single-ratio transformer


Explanation:
I believe "ratio" refers to the current ratio bw primary & secondary windings; in charts on GE's website they use the terms single-ratio and dual-ratio transformers, whose ratios can be, e.g., 200:5 or 200/400:5, respectively


    Reference: http://www.geindustrial.com/pm/products/transfrm/indcurr.pdf
Alexandra Potts
Italy
Native speaker of: Native in EnglishEnglish, Native in SpanishSpanish
PRO pts in pair: 111
Login to enter a peer comment (or grade)

1 hr   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): -1
one to one transformer


Explanation:
as opposed to the variable ratio or switch over transformers.

Dalton

Jose Alonso
PRO pts in pair: 39

Peer comments on this answer (and responses from the answerer)
disagree  two2tango: fixed does not mean 1:1
1 hr
Login to enter a peer comment (or grade)

1 hr   confidence: Answerer confidence 2/5Answerer confidence 2/5
single pole transformer


Explanation:
See if it (single polarity) fits your context. This is another idea for which I found the following references:

co-based
... Loss variation(-55-125°C), <15%, <15%, <15%. Application, Single pole transformer,
filter, inductor, EMC differential mode filter, common mode choke, EAS tags ...
www.amorphous.com.cn/english/products/ ribbons/co-based.htm - 44k - Cached - Similar pages
[ More results from www.amorphous.com.cn ]

RE: Pole transformer spec
... net>" <[email protected]> Hi Steve The impedance of a single pole transformer is
not critical for tesla application. Impedance becomes important when two or ...
www.pupman.com/listarchives/ 2001/November/msg00167.html - 4k - Cached - Similar pages

[PDF] MIL-HDBK-1004/2A 15 JANUARY 1992 SUPERSEDING MIL-HDBK-1004/2 31 ...
File Format: PDF/Adobe Acrobat - View as HTML
... 6 3 Wood Pole Sizes for Single Pole Transformer Installations.....
7 4 Conductor Sizes for Overhead Lines ...
www.efdlant.navfac.navy.mil/criteria/ documents/MH/1004_2A.PDF - Similar pages

fe-based
... Application, single pole transformer, filter, reactor, middle frequency transformer,
Distribution transformer, saturable reactor, pulse compressor. Specifications: ...
www.atmcn.com/nac/nac-eng/products/ ribbons/fe-based.htm - 33k - Cached - Similar pages


Luis Rey Ballesteros (Luiroi)
Local time: 10:05
Native speaker of: Native in SpanishSpanish
PRO pts in pair: 3743
Login to enter a peer comment (or grade)

2 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +1
fixed-ratio transformer


Explanation:
The main characteristic of a transformer is its turn-ratio, meaning the ratio between the amount of wire turns in the primary and secondary coils.
For most transformers this is a fixed number, since they are constructed turning wire around an iron sreucture and remain that way for all of their useful life, They are called fixed-ratio transformers.
A minority of transformers have built-in devices to modify one or both coils in order to cnange their ratio. Typical are transformers used to correct a primary voltage different fron its nominal value (usually lower). They are called variable-ratio transformers.

two2tango
Argentina
Local time: 13:05
Native speaker of: Spanish
PRO pts in pair: 724

Peer comments on this answer (and responses from the answerer)
agree  Fabio Descalzi: Aquí estoy, colaborando con la campaña de cierre de KudoZ...
1620 days
Login to enter a peer comment (or grade)

11 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
single-ratio transformer


Explanation:
Transformer with one secondary voltage level

Michael O' Brien
Spain
Local time: 18:05
PRO pts in pair: 33
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.