English term
Delta Closure
English to Arabic
Tech/Engineering
Electronics / Elect Eng
Secondary Electrical Circuit
Hello,
Eid Moubarak.
"The secondary circuit of the EAF electrical system consists of five major components:delta closure, power cable, bus tube/conducting arm, electrode clamp/holder and the electrode".
Thanks a lot
Eid Moubarak.
"The secondary circuit of the EAF electrical system consists of five major components:delta closure, power cable, bus tube/conducting arm, electrode clamp/holder and the electrode".
Thanks a lot
Proposed translations
(Arabic)
1 +1 | أداة إغلاق توصيل دلتا | Shazly |
5 | اقفال مثلثي - اقفال دالتا | Raouf Malek |
Proposed translations
+1
2 hrs
Selected
أداة إغلاق توصيل دلتا
جهاز إغلاق توصيل دلتا
(توصيل دلتا هو طريقة الملفات الثانوية للمحول كالمثلث (دلتا
The secondary circuit of the EAF transformer terminates at low voltage bushings, which are attached to the delta closure, which consists of a series of copper plates, tubes or both. These are arranged do that the secondary windings of the transformer are joined to form a closed circuit. Most of this equipment is located within the transformer vault to assure a secure, clean environment. The delta closure protrudes through the wall of the vault adjacent to the EAF and connectors are provided to attach to one end of the furnace power cables; the other end being attached to either the current conducting arms of the furnace or the busbar.
--------------------------------------------------
Note added at 13 hrs (2006-12-30 12:35:28 GMT)
--------------------------------------------------
أدوات إغلاق توصيل دلتا
(توصيل دلتا هو طريقة الملفات الثانوية للمحول كالمثلث (دلتا
The secondary circuit of the EAF transformer terminates at low voltage bushings, which are attached to the delta closure, which consists of a series of copper plates, tubes or both. These are arranged do that the secondary windings of the transformer are joined to form a closed circuit. Most of this equipment is located within the transformer vault to assure a secure, clean environment. The delta closure protrudes through the wall of the vault adjacent to the EAF and connectors are provided to attach to one end of the furnace power cables; the other end being attached to either the current conducting arms of the furnace or the busbar.
--------------------------------------------------
Note added at 13 hrs (2006-12-30 12:35:28 GMT)
--------------------------------------------------
أدوات إغلاق توصيل دلتا
Note from asker:
Mr Ahmed, would you please post the source or link of the paragraph you quoted..regards. |
4 KudoZ points awarded for this answer.
Comment: "Thanks a lot."
2 hrs
Discussion
http://www.energymanagertraining.com/iron_steel/Electric_arc...