FET Fault

12:07 Mar 30, 2016
English to Polish translations [PRO]
Tech/Engineering - Automation & Robotics / Inne
English term or phrase: FET Fault
Alarm FET Fault
Main Water Valve FET Fault
Hopper Roll Actuator FET Fault
Horn FET Fault
Filter Shaker Motor FET Fault

Czy na pewno chodzi o błąd tranzystora polowego (silnika, zaworu, alarmu, itp.)?
indert
Poland
Local time: 06:14

Summary of reference entries provided
Field-Effect Transistor (FET) Protection
geopiet

Discussion entries: 3





  

Reference comments


23 hrs
Reference: Field-Effect Transistor (FET) Protection

Reference information:
Field-Effect Transistor (FET) is a type of transistor that when used with module software can be used to monitor and control current flow on module
outputs. The FET protection strategy is used to prevent module damage in the event of excessive current flow.

The SJB utilizes a FET protective circuit strategy for many of its outputs (for example, a headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shut down (turns off the voltage or ground provided by the module) when a fault event
is detected. A continuous DTC is stored at the fault event and a cumulative counter is started.

When the demand for the output is no longer present, the module resets the FET circuit protection to allow the circuit to function. The next time the
driver requests a circuit to activate that has been shut down by a previous short (FET protection) and the circuit remains shorted, the FET protection
shuts off the circuit again and the cumulative counter advances.

When the excessive circuit load occurs often enough, the module shuts down the output until a repair procedure is carried out. Each FET protected
circuit has 3 predefined levels of short circuit tolerance based on the harmful effect of each circuit fault on the FET and the ability of the FET to
withstand it. A module lifetime level of fault events is established based upon the durability of the FET. If the total tolerance level is determined to be
600 fault events, the 3 predefined levels would be 200, 400 and 600 fault events.

When each tolerance level is reached, the continuous DTC that was stored on the first failure cannot be cleared by a command to clear the continuous
DTCs. The module does not allow this code to be cleared or the circuit restored to normal operation until a successful self-test proves that the fault has
been repaired. After the self-test has successfully completed (no on-demand DTCs present), DTC B106E and the associated continuous DTC (the DTC
related to the shorted circuit) automatically clears and the circuit function returns.

When the first or second level is reached, the continuous DTC (associated with the short circuit) sets along with DTC B106E. These DTCs can be
cleared using the module on-demand self-test, then the Clear DTC operation on the scan tool (if the on-demand test shows the fault corrected). The
module never resets the fault event counter to zero and continues to advance the fault event counter as short circuit fault events occur.

If the number of short circuit fault events reach the third level, then DTCs B106F and B1342 set along with the associated continuous DTC. This DTC
cannot be cleared and the module must be replaced.

The SJB FET protected output circuits for the stoplamp system are the LH and RH rear stoplamp output circuits.

http://goo.gl/chAayN

geopiet
Native speaker of: Native in PolishPolish
PRO pts in category: 4
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:

Your current localization setting

English

Select a language

Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search