3 | système d'étalonnage par déplacement d'eau |
|
waterdraw system (water draw system) système d'étalonnage par déplacement d'eau Explanation: Une explication en anglais The water draw method is one of the preferred calibration techniques. It involves displacing or “drawing off” the volume of water between the prover detectors into field test measures which are calibrated traceable to the National Institute of Standards and Technology (NIST). Clear, deaerated water is selected as the test medium because of its stable characteristics, availability, and the relatively low effects its viscosity and surface tension has on drain time through the field test measure. Reference: http://www.industrie.gouv.fr/metro/reglemen/textes/cir-90101... |
| |