English term or phrase: fail-off
If the programmable controller is of conservative design and incorporates internal failure detection with fail-off action - including a proven reliable watchdog timer - then the programmable controller can imitate the failure mode of a relay system, reducing troubleshooting difficulty and false trips.
O María Elena Guerrero
Spain
Local time: 13:50
sensor de cortocircuito
Explanation:
The most common malfunction in solid state dimmers is a failed thyristor (triac or SCR). They can
either "fail on", in which the light cannot be turned off, of "fail off", in which the light cannot be turned
on. A "failed off" condition also may cause a resistor on the circuit board to burn. This failure is
almost always caused by a short in the load it controls. The short can be in the cable, in the
connectors, in the light fixture, or in the bulb itself. Although the dimmer circuit breaker or fuse will
open, it may not be fast enough to save the thyristor and the thyristor will need to be replaced.
Please check the load: plug it into a known good wall outlet before plugging it into other dimming
channels. Caution, a short in the load may trip a building breaker.
Selected response from:

Alicia Jordá
Local time: 13:50
Grading comment
Muchas gracias, Alice
4 KudoZ points were awarded for this answer



Summary of answers provided
4sensor de cortocircuito
Alicia Jordá
4acción de apagado por falla...
Gabriel Aramburo Siegert


  

Answers


13 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
sensor de cortocircuito


Explanation:
The most common malfunction in solid state dimmers is a failed thyristor (triac or SCR). They can
either "fail on", in which the light cannot be turned off, of "fail off", in which the light cannot be turned
on. A "failed off" condition also may cause a resistor on the circuit board to burn. This failure is
almost always caused by a short in the load it controls. The short can be in the cable, in the
connectors, in the light fixture, or in the bulb itself. Although the dimmer circuit breaker or fuse will
open, it may not be fast enough to save the thyristor and the thyristor will need to be replaced.
Please check the load: plug it into a known good wall outlet before plugging it into other dimming
channels. Caution, a short in the load may trip a building breaker.


    Reference: http://www.dovesystems.com/pages/pdf/manuals/sm6man.pdf
Alicia Jordá
Local time: 13:50
Specializes in field
Native speaker of: Spanish
PRO pts in category: 26
Grading comment
Muchas gracias, Alice
Login to enter a peer comment (or grade)

2 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
acción de apagado por falla...


Explanation:
Good luck.

Gabriel Aramburo Siegert
Local time: 06:50
Specializes in field
Native speaker of: Native in SpanishSpanish
PRO pts in category: 107
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search