écran de cantonnement

English translation: smoke reservoir screen, smoke channelling screen

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
French term or phrase:écran de cantonnement
English translation:smoke reservoir screen, smoke channelling screen
Entered by: egunn

11:53 Apr 14, 2005
French to English translations [PRO]
Tech/Engineering - Construction / Civil Engineering
French term or phrase: écran de cantonnement
Écran de cantonnement : séparation verticale placée en sous-face de la toiture ou du plafond, de façon à s'opposer à l'écoulement latéral de la fumée et des gaz
de combustion.

Anyone know the standard technical term for this in English? Thanks in advance for any suggestions...
egunn
Local time: 18:17
smoke reservoir screen
Explanation:
From my notes:
Cantonnement, écran de Smoke reservoir screen [MitchellS&F2, p355-356], smoke curtain

The ref. describes "smoke reservoirs" and includes a diagram showing "reservoir screens", i.e. downstands from the ceiling (vented ceiling) which prevent smoke spreading laterally.

Another diagram shows downstands beneath a balcony, called "channelling screens", which direct smoke coming from inside the building directly to free air, i.e. preventing smoke moving across the face of the building.

Smoke curtain [a development on the above, it would seem]
-a component for forming a smoke barrier ?fail safe, i.e to drop if electricity fails ,testing- .75 to 1 m/s descending speed, for operation of 600 deg C, 30 minutes, fire resistance to BS 476 Part 23
-linear installation, allow 400 mm curtain overlap.
-angle installation , minimum curtain overlap
- also called smoke channeling screen in shopping malls in UK , for channelling smoke from the shops into the atrium for a 2-storey shopping mall, with smoke then vented to outside from the atrium, by smoke vent or otherwise,
[http://www.arch.hku.hk/~kpcheung/fire/fire-n5.htm]

A smoke reservoir must be at least 1.5m deep measured from the lowest point
... the smoke reservoir in a building where there is no suspended ceiling, ...
www.scotland.gov.uk/library2/br/brd-14.asp

Use of a downstand to create a smoke. reservoir. ... used as an extra
smoke reservoir with a. smoke screen around the balcony ...
erg.ucd.ie/EC2000/EC2000_PDFs/fire_safety_in_atria.pdf
Selected response from:

Bourth (X)
Local time: 19:17
Grading comment
Many thanks for all answers and comments.
4 KudoZ points were awarded for this answer



Summary of answers provided
4 +1smoke reservoir screen
Bourth (X)
3baffle ???
Robert Frankling
3separation shield
Francis MARC


  

Answers


26 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5
écran de cantonnement
separation shield


Explanation:
=

Francis MARC
Lithuania
Local time: 20:17
Native speaker of: Native in FrenchFrench
PRO pts in category: 190
Login to enter a peer comment (or grade)

24 mins   confidence: Answerer confidence 3/5Answerer confidence 3/5
écran de cantonnement
baffle ???


Explanation:
...sounds like a "baffle" or "baffle plate"

... A ruptured or warped baffle plate could cause a warp core breach. ...
delta radiation when a baffle plate ruptured on board a J class training vessel. ...
www.memory-alpha.org/en/wiki/Baffle_plate - 11k - 12 avr 2005

F2 exhausts ive got off ebay have had the baffle plates in the endcans drilled out. ...
www.yamaha-rd.com/forum/topic-19537.html

--------------------------------------------------
Note added at 26 mins (2005-04-14 12:19:53 GMT)
--------------------------------------------------

complete gas burner assembly clear of the combustion ... Remove the boiling
plate, combustion chamber baffle. and simmering plate. ...
www.aga-ranges.com/pdfconsumer/ TWO%20AND%20FOUR%20OVEN%20INSTALLATION%20MANUAL.pdf

--------------------------------------------------
Note added at 26 mins (2005-04-14 12:20:23 GMT)
--------------------------------------------------

Water-tube boiler and burner - [ Traduire cette page ]
... gas derived from the burner is present within a combustion chamber. ...
time of burning-reaction ongoing gas downstream of the second baffle plate, ...
www.freepatentsonline.com/6041743.html

--------------------------------------------------
Note added at 28 mins (2005-04-14 12:22:01 GMT)
--------------------------------------------------

Glossary of Common Hearth and Heating Terms - [ Traduire cette page ]
... BAFFLE PLATE - A partition inside an appliance to control the flow of ...
Colorless, odorless noncombustible gas produced by the complete combustion of ...
www.wetaskiwincoop.com/Tips/hearthglossary.htm

Robert Frankling
Local time: 12:17
Native speaker of: English
PRO pts in category: 53
Login to enter a peer comment (or grade)

57 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +1
écran de cantonnement
smoke reservoir screen


Explanation:
From my notes:
Cantonnement, écran de Smoke reservoir screen [MitchellS&F2, p355-356], smoke curtain

The ref. describes "smoke reservoirs" and includes a diagram showing "reservoir screens", i.e. downstands from the ceiling (vented ceiling) which prevent smoke spreading laterally.

Another diagram shows downstands beneath a balcony, called "channelling screens", which direct smoke coming from inside the building directly to free air, i.e. preventing smoke moving across the face of the building.

Smoke curtain [a development on the above, it would seem]
-a component for forming a smoke barrier ?fail safe, i.e to drop if electricity fails ,testing- .75 to 1 m/s descending speed, for operation of 600 deg C, 30 minutes, fire resistance to BS 476 Part 23
-linear installation, allow 400 mm curtain overlap.
-angle installation , minimum curtain overlap
- also called smoke channeling screen in shopping malls in UK , for channelling smoke from the shops into the atrium for a 2-storey shopping mall, with smoke then vented to outside from the atrium, by smoke vent or otherwise,
[http://www.arch.hku.hk/~kpcheung/fire/fire-n5.htm]

A smoke reservoir must be at least 1.5m deep measured from the lowest point
... the smoke reservoir in a building where there is no suspended ceiling, ...
www.scotland.gov.uk/library2/br/brd-14.asp

Use of a downstand to create a smoke. reservoir. ... used as an extra
smoke reservoir with a. smoke screen around the balcony ...
erg.ucd.ie/EC2000/EC2000_PDFs/fire_safety_in_atria.pdf


Bourth (X)
Local time: 19:17
Specializes in field
Native speaker of: Native in EnglishEnglish
PRO pts in category: 4135
Grading comment
Many thanks for all answers and comments.

Peer comments on this answer (and responses from the answerer)
agree  Robert Frankling: "smoke channelling screen" is easy to visualize
25 mins
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:

Your current localization setting

English

Select a language

Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search