French term or phrase: résistance série secteur
Cette résistance série secteur doit être pontée en cas de secteurs à valeurs ohmiques plus 'élevées

Similar to previous question but context seems different.
John Garside
Canada
Local time: 21:54
mains serial resistance
Explanation:
pontée = shorted out, bypassed, jumpered

The explanation is as you correctly suppose the same as before, it is only a correction for the case where the mains supply itself has a non negligible resistance (leads, transformer impedance etc.), this one should be included in the evaluation of the so called "résistance secteur". If it is too high the abovementionned resistance should be shorted out to get a not to high fianl value.
Selected response from:

Yves Georges
France
Local time: 03:54
Grading comment
Your answer was a big help. Got me on the right track. Frankly I prefered the second answer (supply impedence) but my text had already been returned to the customer when that came in so yours was of more immeadiate value.

Thanks
2 KudoZ points were awarded for this answer

Advertisement


Summary of answers provided
4mains input series resistor
Tony M
na +1mains serial resistance
Yves Georges


  

Answers


1 hr peer agreement (net): +1
mains serial resistance


Explanation:
pontée = shorted out, bypassed, jumpered

The explanation is as you correctly suppose the same as before, it is only a correction for the case where the mains supply itself has a non negligible resistance (leads, transformer impedance etc.), this one should be included in the evaluation of the so called "résistance secteur". If it is too high the abovementionned resistance should be shorted out to get a not to high fianl value.


    25 years of instrumentation
Yves Georges
France
Local time: 03:54
Native speaker of: Native in FrenchFrench
PRO pts in pair: 75
Grading comment
Your answer was a big help. Got me on the right track. Frankly I prefered the second answer (supply impedence) but my text had already been returned to the customer when that came in so yours was of more immeadiate value.

Thanks

Peer comments on this answer (and responses from the answerer)
agree  Tony M: correct understanding, but not the correct term! It should be 'series' (not serial) and 'resistor' (not resistance)
16 hrs
Login to enter a peer comment (or grade)

1538 days   confidence: Answerer confidence 4/5Answerer confidence 4/5
mains input series resistor


Explanation:
Y-G has correctly interpreted the term, but I believe this would be the more accurate expression in EN.

(My originally-posted answer was wrong!)

Tony M
France
Local time: 03:54
Native speaker of: Native in EnglishEnglish
PRO pts in pair: 14157
Login to enter a peer comment (or grade)




Return to KudoZ list


KudoZ™ translation help
The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.



See also:



Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search