German term or phrase:Nulleiterpotenzial
English translation:neutral conductor potential
Entered by: Craig Meulen

15:17 Feb 23, 2008
German to English translations [PRO]
Tech/Engineering - Electronics / Elect Eng
German term or phrase: Nulleiterpotenzial
Da das Stecksystem keine eindeutige Polung zulässt ist zu Beachten das dass Nulleiterpotenzial nicht definiert an den mit -N- gekennzeichneten Klemmen und Leitern anliegt.


Before I write to my client, can someone confirm my suspicion that this sentence makes no sense? Or please tell me what they really meant so I don't have to wait until Monday for the client!!

It's part of the operating manual for a mobile exhibition stand, in the section about connecting the stand's power unit to the mains via a "3.pol. Schutzkontakt-Steckdose". Thank you.
Craig Meulen
United Kingdom
Local time: 08:45
neutral conductor potential
Explanation:
References

and the 120 circuit-breaker remains inoperative at least when the *neutral conductor potential* is within the range of normal operation, while on the occurrence of a dangerous potential on the frame due to an insulation 125 fault or the like

Nulleiter m, Nuller m (coll.) (Drehstrom) / neutral o. mid-point conductor o. wire, neutral, zero conductor o. wire
(Ernst)


--------------------------------------------------
Note added at 55 Min. (2008-02-23 16:13:12 GMT)
--------------------------------------------------

My interpretation of the sentence

"Da das Stecksystem keine eindeutige Polung zulässt ist zu Beachten das dass Nulleiterpotenzial nicht definiert an den mit -N- gekennzeichneten Klemmen und Leitern anliegt."

is as follows:

Since the plug-and-socket connector is not reverse polarity protected, there is no guarantee that terminal clamps and conductors marked or labelled with "N" have the electric potential of the neutral conductor.

Note
A plug-and-socket connector system like the "Schuko-System" (Schutzkontakt-Steckdose/Schutzkontaktstecker) is not protected against switching poles. (s.http://de.wikipedia.org/wiki/Schuko)


--------------------------------------------------
Note added at 1 Tag1 Stunde (2008-02-24 16:25:06 GMT)
--------------------------------------------------

Sorry, I forgot to state the origin of the text fragment (... neutral conductor potential is within the range of normal operation ...) quoted above. Here it is: http://www.wikipatents.com/gb/535446.html
Selected response from:

sci-trans
Local time: 09:45
Grading comment
Thank you very very much for your help!
4 KudoZ points were awarded for this answer



Summary of answers provided
4 +2neutral conductor potential
sci-trans


  

Answers


9 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): +2
neutral conductor potential


Explanation:
References

and the 120 circuit-breaker remains inoperative at least when the *neutral conductor potential* is within the range of normal operation, while on the occurrence of a dangerous potential on the frame due to an insulation 125 fault or the like

Nulleiter m, Nuller m (coll.) (Drehstrom) / neutral o. mid-point conductor o. wire, neutral, zero conductor o. wire
(Ernst)


--------------------------------------------------
Note added at 55 Min. (2008-02-23 16:13:12 GMT)
--------------------------------------------------

My interpretation of the sentence

"Da das Stecksystem keine eindeutige Polung zulässt ist zu Beachten das dass Nulleiterpotenzial nicht definiert an den mit -N- gekennzeichneten Klemmen und Leitern anliegt."

is as follows:

Since the plug-and-socket connector is not reverse polarity protected, there is no guarantee that terminal clamps and conductors marked or labelled with "N" have the electric potential of the neutral conductor.

Note
A plug-and-socket connector system like the "Schuko-System" (Schutzkontakt-Steckdose/Schutzkontaktstecker) is not protected against switching poles. (s.http://de.wikipedia.org/wiki/Schuko)


--------------------------------------------------
Note added at 1 Tag1 Stunde (2008-02-24 16:25:06 GMT)
--------------------------------------------------

Sorry, I forgot to state the origin of the text fragment (... neutral conductor potential is within the range of normal operation ...) quoted above. Here it is: http://www.wikipatents.com/gb/535446.html


sci-trans
Local time: 09:45
Specializes in field
Native speaker of: German
PRO pts in category: 43
Grading comment
Thank you very very much for your help!

Peer comments on this answer (and responses from the answerer)
agree  hazmatgerman (X): Ja.
21 hrs

agree  Veronika Neuhold
1 day 19 hrs
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search