Source text - Russian 6.1. Условия срабатывания защит
Энергоблок должен быть немедленно остановлен действием защит или персоналом в случаях:
• повышения абсолютного давления в конденсаторе ПТ выше 15 кПа (101,2 кПа при атмосферном давлении 760 мм рт. ст.) в конденсационном режиме;
• отключения обеих ГТУ;
• наличия внешних неисправностей генератора ПТ в режиме останова.
Нагрузка энергоблока должна быть снижена действием защит или персоналом в случаях:
• повышения абсолютного давления в конденсаторе ПТ выше 15 кПа (101,2 кПа при атмосферном давлении 760 мм рт. ст.) в теплофикационном режиме;
Локальные защиты энергоблока должны обеспечить безопасную работу оборудования в случаях:
• повышения давления в конденсаторе ПТ выше 50 кПа;
• повышения давления в расширителе непрерывной продувки ВД выше 0,93 МПа.
6.2. Разработка дерева событий
В данном разделе разработано дерево событий, ведущих к возникновению аварийной ситуации. Анализ причин срыва вакуума в конденсаторе позволяет снизить вероятность возникновения аварийной ситуации. С помощью дерева событий рассмотрены все события, приводящие к аварии. Применение системного подхода при составлении дерева событий позволяет повысить надежность работы энергоблока.
6.3. Мероприятия по защите технологического оборудования
В состав АСУТП энергоблока входит подсистема защит. Эта подсистема обеспечивает безопасную работу оперативного персонала и теплоэнергетического оборудования путем экстренного автоматического перевода защищаемого оборудования в безопасное состояние в случае возникновения аварийной или предаварийной ситуации. На энергоблоке ПГУ-325 алгоритмы ТЗ реализованы программным путем на средствах ПТК ТПТС-51.
Translation - English 6.1. Conditions of safety system response
The power-generating unit must be shutdown immediately by the safety system or personnel actions in the following cases:
• increase of absolute pressure in the steam turbine condenser higher than 15 kPa (101,2 kPa for atmospheric pressure of 760 mm of mercury) in the condensation mode;
• shutdown of both gas-turbine units;
• external malfunction of the steam turbine generator in the shutdown mode.
Power-generating unit load must be decreased by safety system or personnel actions in the following cases:
• increase of absolute pressure in the steam turbine condenser higher than 15 kPa (101,2 kPa for atmospheric pressure of 760 mm of mercury) in the heat-extraction mode;
• external malfunction of the steam turbine generator (idle mode);
• feed-water pump shutdown.
Local safety systems of the power-generating unit must ensure safe equipment operation in the following cases:
• increase of steam turbine condenser pressure higher than 50 kPa;
• increase of pressure in the high-pressure continuous purging expander higher than 0,93 MPa.
6.2. Event Tree development
In this section, an Event Tree for situations that lead to emergency cases was developed. The condenser vacuum breaking cause analysis allows that emergency situation probability is lowered. With the help of the Event Tree all the situations that lead to the accident are considered. Application of the systematic approach for the Event Tree creating makes possible to increase the safety of power-generating unit operation.
6.3. Technological equipment safety measures
Industrial control system of the power-generating unit includes a safety subsystem. This subsystem ensures safe work for the operating personnel and technological equipment by urgent automatic transfering of the protected equipment into the secure state in case of any accident-prone or emergency situation. At CCP-325 technological safety algorithms are programmed in the program-technical units TPTC-51 software.