Operator's Manual
Cutting Wire Rope
CAUTION
The ends of type ZB wire rope must be ***fuse welded***. Failure to do so may cause the core to slip and/or the strands to loosen causing major wire rope damage.
When wire rope is to be cut, seizing should be placed on each side of the point where the wire rope is to be cut, to keep the strands in place. On preformed wire rope, one seizing on each side of the cut is enough. On non-preformed wire rope less than 7/8 in (23mm) diameter, two seizings are recommended. On non-preformed wire rope over 7/8 in (23mm) diameter, three seizings are recommended. Wire or strand must be used to seize non-preformed wire rope. Wire, strand, or heavy tape may be used to seize preformed wire rope.
Three Basic methods of cutting wire rope are recommended:
1. Abrasive cutting tools.
2. Shearing tools. (Wire cutters on small wire rope, a wire rope cutter, and hammer for larger wire ropes.)
3. Oxy/Acetylene fuel torch. A torch can be used to cut type ZB wire rope only. The heat will ***fuse weld*** the end, which is OK for type ZB , but not for other types which are not to be ***fuse welded***.
Cutting Wire Rope
CAUTION
The ends of type ZB wire rope must be ***fuse welded***. Failure to do so may cause the core to slip and/or the strands to loosen causing major wire rope damage.
When wire rope is to be cut, seizing should be placed on each side of the point where the wire rope is to be cut, to keep the strands in place. On preformed wire rope, one seizing on each side of the cut is enough. On non-preformed wire rope less than 7/8 in (23mm) diameter, two seizings are recommended. On non-preformed wire rope over 7/8 in (23mm) diameter, three seizings are recommended. Wire or strand must be used to seize non-preformed wire rope. Wire, strand, or heavy tape may be used to seize preformed wire rope.
Three Basic methods of cutting wire rope are recommended:
1. Abrasive cutting tools.
2. Shearing tools. (Wire cutters on small wire rope, a wire rope cutter, and hammer for larger wire ropes.)
3. Oxy/Acetylene fuel torch. A torch can be used to cut type ZB wire rope only. The heat will ***fuse weld*** the end, which is OK for type ZB , but not for other types which are not to be ***fuse welded***.
Proposed translations
(Portuguese)
5 +2 | soldado por fusão |
coolbrowne
![]() |
5 | Soldagem por fusão |
Nick Taylor
![]() |
3 | fundido a solda |
sflor (X)
![]() |
Change log
Feb 2, 2012 03:26: coolbrowne changed "Edited KOG entry" from "<a href="/profile/1415683">Rebelo Júnior's</a> old entry - "fuse welded"" to ""soldado por fusão""
Proposed translations
+2
3 hrs
Selected
soldado por fusão
A soldadura por fusão ou autógena ocorre quando as partes a serem soldadas são aquecidas (ao ponto de fusão) e se soldam entre si, geralmente sem necessidade adicionar material de enchimento. No caso desta pergunta, os filamentos do cabo devem ser soldados por fusão para garantir a integridade do mesmo.
--------------------------------------------------
Note added at 3 hrs (2012-01-30 22:27:58 GMT)
--------------------------------------------------
AHA! Enquanto escrevia minha explicação, apareceu o substantivo "Soldagem por fusão" que é bastante próximo da resposta correta. Não retiro esta resposta porque, além de estar na classe gramatical correta (verbo), contém a requerida explicação.
--------------------------------------------------
Note added at 3 hrs (2012-01-30 22:27:58 GMT)
--------------------------------------------------
AHA! Enquanto escrevia minha explicação, apareceu o substantivo "Soldagem por fusão" que é bastante próximo da resposta correta. Não retiro esta resposta porque, além de estar na classe gramatical correta (verbo), contém a requerida explicação.
4 KudoZ points awarded for this answer.
Comment: "Obrigado!"
13 mins
fundido a solda
Pelo que entendi, "as pontas do cabo metálico do tipo ZB devem ser fundidas a solda."
Seria a minha sugestão.
Seria a minha sugestão.
3 hrs
Soldagem por fusão
Soldagem por fusão
Discussion