Glossary entry (derived from question below)
Portuguese term or phrase:
barra dupla a quatro chaves
English translation:
four switchgear double busbar
Added to glossary by
rhandler
May 30, 2005 03:10
19 yrs ago
2 viewers *
Portuguese term
barra dupla a quatro chaves
Portuguese to English
Tech/Engineering
Energy / Power Generation
electric power generation
o esquema de manobra é em barra dupla a quatro chaves com 3 vãos de entrada de geradores
Proposed translations
(English)
5 +1 | four switchgear double busbar | rhandler |
3 | double bar and four keys | António Ribeiro |
Proposed translations
+1
10 hrs
Selected
four switchgear double busbar
Pode-se usar bus-bar, bus bar ou busbar, para barra/barramento. Chaves, neste contexto, é switchgear. Alguns exemplos:
Switchgear, boards, relays & motors engineering - single busbar or ...
... Please can anyone tell me where it is preferable to have double bus bar over
... Double bus bar enables planned shut down of one bus bar at a time for ...
www.eng-tips.com/viewthread.cfm?qid=119548&page=1
GIS : Gas Insulated Switchgear
... Dimensions per double bus bar bay <Height> (approx. m), 4.0, 4.2, 4.8.
Dimensions per double bus bar bay <Depth> (approx. m), 4.7, 5.7, 6.5 ...
www.tic.toshiba.com.au/website/newtic/gis_1.htm
[PDF] MNS – Modular Low Voltage Switchgear System
File Format: PDF/Adobe Acrobat - View as HTML
... The busbar material is aluminium or copper depending. on the rated current. ... Each of the four switchgear buses can have up. to 32 motors connected. ...
www.abb.fi/.../viewunid/BE6729D85EE55A94C2256C410027B430/ $file/MNS%20-%20Brochure%20-%20English.pdf - Similar pages
Summary of Work - STP Module 4: Substations
... Deliverable:. Amended report S0409 for four switchgear manufacturers included in the study ... S4123: HV Metalclad Busbar Maintenance. Deliverable: ...
www.eatechnology.com/STP_LearnMore_Substations.asp
Switchgear, boards, relays & motors engineering - single busbar or ...
... Please can anyone tell me where it is preferable to have double bus bar over
... Double bus bar enables planned shut down of one bus bar at a time for ...
www.eng-tips.com/viewthread.cfm?qid=119548&page=1
GIS : Gas Insulated Switchgear
... Dimensions per double bus bar bay <Height> (approx. m), 4.0, 4.2, 4.8.
Dimensions per double bus bar bay <Depth> (approx. m), 4.7, 5.7, 6.5 ...
www.tic.toshiba.com.au/website/newtic/gis_1.htm
[PDF] MNS – Modular Low Voltage Switchgear System
File Format: PDF/Adobe Acrobat - View as HTML
... The busbar material is aluminium or copper depending. on the rated current. ... Each of the four switchgear buses can have up. to 32 motors connected. ...
www.abb.fi/.../viewunid/BE6729D85EE55A94C2256C410027B430/ $file/MNS%20-%20Brochure%20-%20English.pdf - Similar pages
Summary of Work - STP Module 4: Substations
... Deliverable:. Amended report S0409 for four switchgear manufacturers included in the study ... S4123: HV Metalclad Busbar Maintenance. Deliverable: ...
www.eatechnology.com/STP_LearnMore_Substations.asp
4 KudoZ points awarded for this answer.
Comment: "Obrigado."
17 mins
double bar and four keys
Uma sugestão.
Something went wrong...