***Load Shed Relays***
Thirteen relay contacts, rated 0.5A, 125VDC, operate on a signal from the DMC PLC, based on Bus Overload or Genset Failure. Relay operation levels are programmable from the Load Control and Load Priority Control touchscreens.
Thirteen relay contacts, rated 0.5A, 125VDC, operate on a signal from the DMC PLC, based on Bus Overload or Genset Failure. Relay operation levels are programmable from the Load Control and Load Priority Control touchscreens.
Proposed translations
(Spanish)
4 +5 | relés para desconexión de carga | Shawn Keeney |
4 | relés protectores | Terje Ostgaard |
Proposed translations
+5
1 hr
Selected
relés para desconexión de carga
Se usa para evitar que las baterias se descarguen completamente.
Untitled
File Format: PDF/Adobe Acrobat - View as HTML
... f) La DO deberá considerar la conexión de relés de desconexión de carga por
subtensión. para prevenir los riesgos de un colapso de tensión. TITULO 6-10 ...
suse-sing.cdec-sing.cl/pdf_docs/NT_de_SyCS.pdf - Similar pages
[PDF] Microsoft PowerPoint - presentaJMC.ppt
File Format: PDF/Adobe Acrobat - View as HTML
... SING Es necesario reafirmar los relés de desconexión de carga por parte de los clientes
Juegan un rol necesario que complementa la respuesta primaria. ...
power.die.uchile.cl/BDMC/documentos/presentaJMC2.pdf
Technical Specification Model C593 Model C596File Format: PDF/Adobe Acrobat - View as HTML
... Load Shed Relay. Load Shed Level. :-. Battery level < 10.8 V. Battery level < 21.6 V. Analogue Status Signal. Mains OK. Battery Low ...
www.emspower.com/Datasheets/C593datasheet.pdf
Untitled
File Format: PDF/Adobe Acrobat - View as HTML
... f) La DO deberá considerar la conexión de relés de desconexión de carga por
subtensión. para prevenir los riesgos de un colapso de tensión. TITULO 6-10 ...
suse-sing.cdec-sing.cl/pdf_docs/NT_de_SyCS.pdf - Similar pages
[PDF] Microsoft PowerPoint - presentaJMC.ppt
File Format: PDF/Adobe Acrobat - View as HTML
... SING Es necesario reafirmar los relés de desconexión de carga por parte de los clientes
Juegan un rol necesario que complementa la respuesta primaria. ...
power.die.uchile.cl/BDMC/documentos/presentaJMC2.pdf
Technical Specification Model C593 Model C596File Format: PDF/Adobe Acrobat - View as HTML
... Load Shed Relay. Load Shed Level. :-. Battery level < 10.8 V. Battery level < 21.6 V. Analogue Status Signal. Mains OK. Battery Low ...
www.emspower.com/Datasheets/C593datasheet.pdf
4 KudoZ points awarded for this answer.
Comment: "gracias, Shawn!"
38 mins
relés protectores
Indice
... contactores auxiliares, relés temporizadores, contactores de potencia, relés protectores de motor, interruptores de levas, interruptores seccionadores, ...
www.automatas.org/moeller/indice_mo.htm - 33k - I hurtigbuffer - Lignende sider
... contactores auxiliares, relés temporizadores, contactores de potencia, relés protectores de motor, interruptores de levas, interruptores seccionadores, ...
www.automatas.org/moeller/indice_mo.htm - 33k - I hurtigbuffer - Lignende sider
Something went wrong...